Function Details ESIE12-0648 Function and Control3. Function Details3.1 Indoor Unit3.1.1 Set Temperature and Control TemperatureThe relationship between "Set temperature by remote controller" and "Control targettemperature" is as shown below.The mark indicates the “Control target temperature” (°C) as an example when the “Settemperature by remote controller” is set there.3.1.2 Thermostat ControlAccording to a difference between the temperature set by the remote controller and the actuallydetected room temperature (1), the thermostat is turned ON or OFF.T: Detected room temperature - Temperature set by remote controllerTro: Room temperature detected when dry operation is startedTr: Room temperature detected by thermistor In normal operationIn coolingIn heatingCoolingHeating14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35˚CSet temperature by remotecontrollerSet temperature by remotecontrollerControl target temperatureControl target temperatureThermostat OFFΔT ≥ +0.5ºCORNormal operation(Thermostat ON)·ΔT ≤ -0.5ºC continues for 1 minute.·ΔT ≤ -2ºCΔT ≤ -0.5ºCORThermostat OFFNormal operation(Thermostat ON)·ΔT ≥ +0.5ºC continues for 1 minute.·ΔT ≥ +2ºC