94Status MessagesStatus messages appear in the fourth line of the display as shownbelow.The left part of the status line indicates the control point of the drive.The center part of the status line indicates the reference location.The last part of the status line gives the present status of the drive.Auto Mode (AUTO)The drive is in Auto mode, which means that Run/Stop control iscarried out via the control terminals and/or serial communication. Seealso Auto Start .Hand Mode (HAND)The drive is in Hand mode, which means that Run/Stop control iscarried out via the keys on the keypad. See also Hand Start.OFF (OFF)OFF/STOP is activated either by means of the keypad, or by the digitalinputs Hand Start and Auto Start, both being a logic ‘0’. See also OFF/STOP .Local Reference (LOCAL)If LOCAL has been selected, the reference is set via the + and - keyson the keypad. See also Display Modes.Remote Controlled Reference (REM.)If REMOTE has been selected, the reference is set via the controlterminals or via serial communication. See also Display Modes.Running (RUNNING)The motor speed now corresponds to the resulting reference.Ramp Operation (RAMPING)The output frequency is changing.Auto Ramp (AUTO RAMP)Parameter 208, Automatic Ramp Up/Down, is enabled. The drive isattempting to avoid a trip from overvoltage by extending its decel ramptime.Sleep Boost (SLEEP .BST)The boost function in parameter 406, Boost Setpoint, is enabled. Thisfunction can only be enabled in Closed Loop operation.DANGER!When inSleep Mode, motor may restart at anytime without warning.Sleep Mode (SLEEP)The energy saving function in parameter 403, Sleep Mode Timer, isenabled. This status message shows that at present the motor has beenstopped by sleep mode. It can restart automatically.DANGER!When inStart Delay mode, motor may restartat any time without warning.Start Delay (START DEL)A start delay time has been programmed in parameter 111, Start Delay.When the delay has passed, the drive will start and ramp up to thereference frequency.DANGER!When inRun Request mode, motor may restartat any time without warning.Run Request (RUN REQ.)A start command has been given, but the motor will not be started untila Run Permission signal is received via a digital input.Jogging (JOG)Jog has been enabled via a digital input or via serial communication.DANGER!When inJog Request, motor may restart at anytime without warning.Jog Request (JOG REQ.)A start command has been given, but the motor will remain stoppeduntil a Run Permission signal is received via a digital input.SETUP180.0% 5.08A 2.15kWAUTO REMOTE RUN40.0HzHANDOFFSTOPRAMPINGJOGGING....STAND BYLOCAL