|
15-71 Slot A Option SW Version15-72 Option in Slot B15-73 Slot B Option SW Version15-74 Option in Slot C015-75 Slot C0/E0 Option SW Version15-76 Option in Slot C115-77 Slot C1/E1 Option SW Version15-9* Parameter Info15-92 Defined Parameters15-93 Modified Parameters15-98 Drive Identification15-99 Parameter Metadata16-** Data Readouts16-0* General Status16-00 Control Word16-01 Reference [Unit]16-02 Reference [%]16-03 Status Word16-05 Main Actual Value [%]16-09 Custom Readout16-1* Motor Status16-10 Power [kW]16-11 Power [hp]16-12 Motor voltage16-13 Frequency16-14 Motor current16-15 Frequency [%]16-16 Torque [Nm]16-17 Speed [RPM]16-18 Motor Thermal16-20 Motor Angle16-22 Torque [%]16-3* Drive Status16-30 DC Link Voltage16-32 Brake Energy /s16-33 Brake Energy /2 min16-34 Heatsink Temp.16-35 Inverter Thermal16-36 Inv. Nom. Current16-37 Inv. Max. Current16-38 SL Controller State16-39 Control Card Temp.16-40 Logging Buffer Full16-49 Current Fault Source16-5* Ref. & Feedb.16-50 External Reference16-52 Feedback [Unit]16-53 Digi Pot Reference16-54 Feedback 1 [Unit]16-55 Feedback 2 [Unit]16-56 Feedback 3 [Unit]16-58 PID Output [%]16-59 Adjusted Setpoint16-6* Inputs & Outputs16-60 Digital Input16-61 Terminal 53 Switch Setting16-62 Analog Input 5316-63 Terminal 54 Switch Setting16-64 Analog Input 5416-65 Analog Output 42 [mA]16-66 Digital Output [bin]16-67 Pulse Input #29 [Hz]16-68 Pulse Input #33 [Hz]16-69 Pulse Output #27 [Hz]16-70 Pulse Output #29 [Hz]16-71 Relay Output [bin]16-72 Counter A16-73 Counter B16-75 Analog In X30/1116-76 Analog In X30/1216-77 Analog Out X30/8 [mA]16-8* Fieldbus & FC Port16-80 Fieldbus CTW 116-82 Fieldbus REF 116-84 Comm. Option Status16-85 FC Port CTW 116-86 FC Port REF 116-9* Diagnosis Readouts16-90 Alarm Word16-91 Alarm Word 216-92 Warning Word16-93 Warning Word 216-94 Ext. Status Word16-95 Ext. Status Word 216-96 Maintenance Word18-** Info & Readouts18-0* Maintenance Log18-00 Maintenance Log: Item18-01 Maintenance Log: Action18-02 Maintenance Log: Time18-03 Maintenance Log: Date and Time18-3* Inputs & Outputs18-30 Analog Input X42/118-31 Analog Input X42/318-32 Analog Input X42/518-33 Analog Out X42/7 [V]18-34 Analog Out X42/9 [V]18-35 Analog Out X42/11 [V]18-36 Analog Input X48/2 [mA]18-37 Temp. Input X48/418-38 Temp. Input X48/718-39 Temp. Input X48/1018-6* Inputs & Outputs 218-60 Digital Input 220-** Drive Closed-loop20-0* Feedback20-00 Feedback 1 Source20-01 Feedback 1 Conversion20-02 Feedback 1 Source Unit20-03 Feedback 2 Source20-04 Feedback 2 Conversion20-05 Feedback 2 Source Unit20-06 Feedback 3 Source20-07 Feedback 3 Conversion20-08 Feedback 3 Source Unit20-12 Reference/Feedback Unit20-2* Feedback/Setpoint20-20 Feedback Function20-21 Setpoint 120-22 Setpoint 220-23 Setpoint 320-7* PID Autotuning20-70 Closed-loop Type20-71 PID Performance20-72 PID Output Change20-73 Minimum Feedback Level20-74 Maximum Feedback Level20-79 PID Autotuning20-8* PID Basic Settings20-81 PID Normal/ Inverse Control20-82 PID Start Speed [RPM]20-83 PID Start Speed [Hz]20-84 On Reference Bandwidth20-9* PID Controller20-91 PID Anti Windup20-93 PID Proportional Gain20-94 PID Integral Time20-95 PID Differentiation Time20-96 PID Diff. Gain Limit21-** Ext. Closed-loop21-0* Ext. CL Autotuning21-00 Closed-loop Type21-01 PID Performance21-02 PID Output Change21-03 Minimum Feedback Level21-04 Maximum Feedback Level21-09 PID Auto Tuning21-1* Ext. CL 1 Ref./Fb.21-10 Ext. 1 Ref./Feedback Unit21-11 Ext. 1 Minimum Reference21-12 Ext. 1 Maximum Reference21-13 Ext. 1 Reference Source21-14 Ext. 1 Feedback Source21-15 Ext. 1 Setpoint21-17 Ext. 1 Reference [Unit]21-18 Ext. 1 Feedback [Unit]21-19 Ext. 1 Output [%]21-2* Ext. CL 1 PID21-20 Ext. 1 Normal/Inverse Control21-21 Ext. 1 Proportional Gain21-22 Ext. 1 Integral Time21-23 Ext. 1 Differentation Time21-24 Ext. 1 Dif. Gain Limit21-3* Ext. CL 2 Ref./Fb.21-30 Ext. 2 Ref./Feedback Unit21-31 Ext. 2 Minimum Reference21-32 Ext. 2 Maximum Reference21-33 Ext. 2 Reference Source21-34 Ext. 2 Feedback Source21-35 Ext. 2 Setpoint21-37 Ext. 2 Reference [Unit]21-38 Ext. 2 Feedback [Unit]21-39 Ext. 2 Output [%]21-4* Ext. CL 2 PID21-40 Ext. 2 Normal/Inverse Control21-41 Ext. 2 Proportional Gain21-42 Ext. 2 Integral Time21-43 Ext. 2 Differentation Time21-44 Ext. 2 Dif. Gain Limit21-5* Ext. CL 3 Ref./Fb.21-50 Ext. 3 Ref./Feedback Unit21-51 Ext. 3 Minimum Reference21-52 Ext. 3 Maximum Reference21-53 Ext. 3 Reference Source21-54 Ext. 3 Feedback Source21-55 Ext. 3 Setpoint21-57 Ext. 3 Reference [Unit]21-58 Ext. 3 Feedback [Unit]21-59 Ext. 3 Output [%]21-6* Ext. CL 3 PID21-60 Ext. 3 Normal/Inverse Control21-61 Ext. 3 Proportional Gain21-62 Ext. 3 Integral Time21-63 Ext. 3 Differentation Time21-64 Ext. 3 Dif. Gain Limit22-** Application Functions22-0* Miscellaneous22-00 External Interlock Delay22-2* No-Flow Detection22-20 Low Power Auto Set-up22-21 Low Power Detection22-22 Low Speed Detection22-23 No-Flow Function22-24 No-Flow Delay22-26 Dry Pump Function22-27 Dry Pump Delay22-28 No-Flow Low Speed [RPM]22-29 No-Flow Low Speed [Hz]22-3* No-Flow Power Tuning22-30 No-Flow Power22-31 Power Correction Factor22-32 Low Speed [RPM]22-33 Low Speed [Hz]22-34 Low Speed Power [kW]22-35 Low Speed Power [HP]22-36 High Speed [RPM]22-37 High Speed [Hz]22-38 High Speed Power [kW]22-39 High Speed Power [HP]22-4* Sleep Mode22-40 Minimum Run Time22-41 Minimum Sleep Time22-42 Wake-up Speed [RPM]22-43 Wake-up Speed [Hz]22-44 Wake-up Ref./FB Difference22-45 Setpoint Boost22-46 Maximum Boost Time22-5* End of Curve22-50 End of Curve Function22-51 End of Curve Delay22-6* Broken Belt Detection22-60 Broken Belt Function22-61 Broken Belt Torque22-62 Broken Belt Delay22-7* Short Cycle Protection22-75 Short Cycle Protection22-76 Interval between Starts22-77 Minimum Run Time22-78 Minimum Run Time Override22-79 Minimum Run Time Override Value22-8* Flow Compensation22-80 Flow Compensation22-81 Square-linear Curve Approximation22-82 Work Point Calculation22-83 Speed at No-Flow [RPM]22-84 Speed at No-Flow [Hz]22-85 Speed at Design Point [RPM]22-86 Speed at Design Point [Hz]22-87 Pressure at No-Flow Speed22-88 Pressure at Rated Speed22-89 Flow at Design Point22-90 Flow at Rated Speed23-** Time-based Functions23-0* Timed Actions23-00 ON Time23-01 ON Action23-02 OFF Time23-03 OFF Action23-04 Occurrence23-1* Maintenance23-10 Maintenance Item23-11 Maintenance Action23-12 Maintenance Time Base23-13 Maintenance Time Interval23-14 Maintenance Date and Time23-1* Maintenance Reset23-15 Reset Maintenance Word23-16 Maintenance Text23-5* Energy Log23-50 Energy Log Resolution23-51 Period Start23-53 Energy Log23-54 Reset Energy Log23-6* Trending23-60 Trend Variable23-61 Continuous Bin Data23-62 Timed Bin Data23-63 Timed Period Start23-64 Timed Period Stop23-65 Minimum Bin Value23-66 Reset Continuous Bin Data23-67 Reset Timed Bin Data23-8* Payback Counter23-80 Power Reference Factor23-81 Energy Cost23-82 Investment23-83 Energy Savings23-84 Cost Savings24-** Appl. Functions 224-1* Drive Bypass24-10 Drive Bypass Function24-11 Drive Bypass Delay Time25-** Cascade Controller25-0* System Settings25-00 Cascade ControllerAppendix Instruction ManualMG20MA22 Danfoss A/S © 10/2014 All rights reserved. 819 9 PreviousNext |