26This appliance must be connected to a grounded, metallic permanent wiring sys-tem or a ground connector should be connected to the ground terminal or wirelead on the appliance.This appliance is manufactured with a frame connected, green or bare ground wire.Connect the appliance cable to the junction box through the CSA or UL-listed conduitconnector. Complete electrical connection according to local codes and ordinances.CONNECT WITH COPPER WIRE ONLY✓ The flexible (4’) armoured cable should be connected directly to the junction box.✓ Do not cut the conduit.✓ A CSA or UL-listed conduit connector must be provided at the junction box.✓ Do not ground to a gas pipe.✓ Do not have a fuse in the grounding or neutral circuit.✓ Fuse both supply (phase) lines.✓ A time delay fuse or circuit breaker is recommended.✓ Connect directly to the fused disconnect (or circuit breaker box) through flexible,armored or non-metallic shealted, copper cable (with grounding wire).✓ If codes permit and a separate grounding wire is used, it is recommended that aqualified electrician determine that the grounding path and wire gauge is inaccordance with local codes.If the appliance is to be completely enclosed in a cabinet, feed the appliancecable through the opening in the cabinet. Make the electrical connection follow-ing the appropriate steps for your installation.1. Disconnect the power supply.2. Remove the junction box cover.3. Connect the appliance cable to the junction box through the CSA or UL-listed con-duit connector.4. Connect the two black wires together with twist-on connectors.5. Connect the two red wires together with twist-on connectors.6. Connect electrical connection according to local codes and ordinances.If local codes PERMIT connecting cabinet-grounding conductor to neutral whitewire in the junction box:7. Crimp the green & yellow (or green) and white oven wires.8. Connect the crimped green & yellow (or green) and white oven cable wires to theneutral (white) wire in the junction box (Fig. 6.1).9. Replace the junction box cover.OR If local codes DO NOT PERMIT connecting cabinet-grounding conductor toneutral white wire in junction box:7. Connect white oven cable wire to neutral (white) wire in junction box (Fig. 6.2).8. Connect the green & yellow (or green) grounding appliance cable wire to a ground-ed wire in the junction box.9. Replace the junction box cover.OR If connecting to a four-wire electrical system:7. Connect white oven cable wire to neutral (white) wire in junction box (Fig. 6.2).8. Connect the green & yellow (or green) appliance cable wire to the green & yellow (orgreen) grounding wire in the junction box.Do NOT connect the green & yellow (or green) appliance cable wire to neutral(white) wire in junction box.9. Replace the junction box cover.electrical connectionTO AVOID ELECTRICAL SHOCKHAZARD, BEFORE INSTALLING THEAPPLIANCE, SWITCH POWER OFF ATTHE SERVICE PANEL AND LOCK THEPANEL TO PREVENT THE POWERF R O M B E I N G S W I T C H E D O NACCIDENTALLY.WARNING3-wire cable frompower supplyBlack wiresJunction boxCSA or UL-listedconduit connectorto applianceRed wiresWhitewiresGreen & yellowwire(or green wire)White wiresJunction boxCSA or UL-listedconduit connectorto applianceRed wiresBlack wiresGreen & yellowwires(or green wires)4-wire cable frompower supplyFig. 6.1Fig. 6.2