133.6 TourThere are 8 programmable Tours. Each Tour consists of up to 42 Preset positions, Patterns,Scans or other Tours (second-level). Using second-level Tours, it can be expanded to over 300functions in a single Tour. However second level Tours will be ignored when called by a Tours.The following example illustrates this concept:If Tour1 has Preset1ÎPreset2ÎTour2ÎTour3 andTour2 has Preset3ÎPreset4 ÎPreset5 ÎTour4andTour3 has Preset6ÎPattern 1andTour4 has Preset7.Tour1 executes as follows:Preset1 Î Preset2 Î Preset3 Î Preset4 Î Preset5 Î Preset6 Î Pattern1 ÎPreset1 Î ... (Repeat)Tour2 executes as follows:Preset3 Î Preset4 Î Preset5 Î Preset7 Î Preset3 … Repeat(Tour4 is still valid if called directly from Tour2.)xxxxx : 16 digits of title for tour label=== : blank preset positionSCAN TYPE : Max (Normal)/ Slow V. Scan/ Fast V. ScanDWELL : 03-99 Sec003 : Preset 003 (1~240)A08 : Auto Scan 08 (1~8)P01 : Pattern 01 (1~4)T02 : Tour 02 (1~8)Follow the steps below to program the Tours:1. Press PRESET + 95 to display the main menu on the monitor. Scroll to Tour and push theJoystick to the right to enter the Tour menu. Or just press the Tour key on the keyboard2. Choose an empty location to be programmed by pushing the Joystick up, down, right, orleft.3. To see a stored preset view, use the Joystick to move the cursor to a stored position. Bypressing PRESET + 93 keys, the camera will move to the stored Preset view.TOUR 01:xxxxxxxxxxxxxxxxSCAN TYPE:NORMAL=== === 003 === === === ===A08 === === === === === ====== T02 === 001 === === ====== === === T08 === === ====== === === === === === ====== === === === === === ===SAVE AND EXIT(ESC TO CANCEL)PRESS FUNCTION KEY AND ROTATEJOYSTICK TO SELECT NUMBER.