151. Press PRESET + 95 keys to display the main menu on the monitor.2. Scroll down to PATTERN and push the Joystick to the right. Or simply press the PRESET+ 80 key rather than use the Main Menu.3. Select the empty Pattern number to be programmed by pushing the Joystick Up or Down.If last column is not 000, a pattern has already been recorded. Patterns can be over written.4. Press the PRESET + 95 keys and control the camera direction and zoom with the Joystick.Your controls will be automatically recorded until you press the PRESET + 95 keys again.You can repeat this procedure until you have the pattern you want. Previously recordedpatterns will be overwritten each time you do this.5. Scroll down to the Save and Exit option and push the Joystick to the right to save and exit.6. You can title the selected Pattern by twisting the Joystick. Rotate the handle clockwise orcounterclockwise to scroll through the alphanumeric characters, push the handle to right orleft to select next or previous space.7. Pressing PRESET + 96 will not save your information and exits to the previous mode.Press the PRESET + 91 key at any programmed position to delete that programmedpattern.NOTE: If total recording time reaches 240 seconds, it will automatically stop for a moment andrestart recording. Previous data will be overwritten.3.8 AlarmNO : Alarm input numberPRIO : Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.PRS : Stored preset number to be called by alarm.IN : NO/NC - normally open /Closed OFF - ignoreOUT : OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.HOLD : Alarm will be held for programmed time (03 to 99 seconds)LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.There are 8 levels of priority. “0” is the highest priority and can be selected Autoscan, Pattern orTour only. “1” - “8” can be selected Preset only. During responding “0” priority alarm, otheralarms won’t be serviced until the “0” priority action is completed.ALARM SETUPNO PRI PRS IN OUT HLD LATCH01 1 001 OFF OFF 3 OFF02 0 A01 OFF OUT1 3 OFF03 1 240 NO OUT1 3 OFF04 2 001 NC OUT4 3 OFF05 1 001 OFF OFF 3 OFF06 8 001 OFF OUT1 3 OFF07 1 240 NO OUT1 3 OFF08 2 001 NC OUT4 3 OFFSAVE AND EXIT(ESC TO CANCEL)