1466 Sflow CommandsCommand ModeGlobal Configuration mode.User GuidelinesThis command has no user guidelines.Exampleconsole(config)#sflow 1 sampling gigabitethernet1/0/2 1500 50sflow sampling (Interface Mode)Use the sflow sampling command in Interface Mode to enable a new sflowsampler instance for this data source if rcvr_idx is valid. Use the "no" form ofthis command to reset sampler parameters to the default.Syntaxsflowrcvr-index samplingsampling-rate [size ]no sflowrcvr-index sampling•rcvr-index — The sFlow Receiver for this sFlow sampler to which flowsamples are to be sent. If no receiver is configured, then no packets will besampled. Only active receivers can be set. If a receiver expires, then allsamplers associated with the receiver will also expire. (Range: 1 - 8).•sampling-rate — The statistical sampling rate for packet sampling fromthis source. A sampling rate of 1 counts all packets. A rate of 0 disablessampling. A value of n means that out of n incoming packets, 1 packet willbe sampled. (Range: 1024 - 65536).•size — The maximum number of bytes that should be copied from thesampler packet (Range: 20 - 256 bytes).Default ConfigurationThere are no samplers configured by default.The default sampling rate is 0.The default maximum header size is 128.