8System MessagesError MessagesError Message DescriptionAddress mark notfoundThe BIOS found a faulty disk sector or could not find a particular disk sector.Alert! Previousattempts atbooting thissystem have failedat checkpoint[nnnn]. For help inresolving thisproblem, pleasenote thischeckpoint andcontact DellTechnical Support.The system failed to complete the boot routine three consecutive times for thesame error. Contact Dell and report the checkpoint code (nnnn) to the supporttechnician.Alert! Securityoverride Jumper isinstalled.The MFG_MODE jumper has been set and AMT Management features are disableduntil it is removed.Attachment failedto respondThe floppy or hard-drive controller cannot send data to the associated drive.Bad command orfile nameEnsure that you have spelled the command correctly, put spaces in the properplace, and used the correct pathname.Bad error-correction code(ECC) on disk readThe floppy or hard-drive controller detected an uncorrectable read error.Controller hasfailedThe hard drive or the associated controller is defective.Data error The floppy or hard drive cannot read the data. For the Windows operating system,run the chkdsk utility to check the file structure of the floppy or hard drive. For anyother operating system, run the appropriate corresponding utility.Decreasingavailable memoryOne or more memory modules may be faulty or improperly seated. Re-install thememory modules and, if necessary, replace them.Diskette drive 0seek failureA cable may be loose or the system configuration information may not match thehardware configuration.79