cfgChassisMaxPowerConservationMode (Read/Write)Description Enables or disables maximum power conservation mode. When enabled, all serversare immediately reduced to their minimum power levels, and all subsequent serverpower allocation requests are denied. In this mode, performance of the servers thatare turned on may be degraded, and additional servers cannot be turned on,regardless of the server priority.Legal Values • 0 (disabled)• 1 (enabled)Default 0 (disabled)cfgChassisPerformanceOverRedundancy (Read/Write)Description Enables or disables server performance over powerredundancy. When enabled, this option favors serverperformance and server powerup, over maintaining powerredundancy. When disabled, the system favors powerredundancy over server performance. When disabled,then if the power supplies in the chassis do not providesufficient power, both for redundancy, as well as fullperformance, then some servers may not be grantedsufficient power for full performance, or may not be turnedon, in order to maintain redundancy.Legal Values • 0 (disabled)• 1 (enabled)Default 1 (enabled)cfgChassisInMaxPowerCapacity (Read Only)Description Indicates the total chassis power budget (in watts) available for chassis operation.Legal Values NoneDefault NonecfgChassisInRedundancyReserve (Read Only)Description Indicates the amount of redundant power (in Watt) in reserve that can be utilized inthe event of an AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to0 (no redundancy).Legal Values 0 (disabled)1 (enabled)Default None140