NOTE: The server must be turned off to change the slot state. All servers must beturned off to change the fabric state. The MAC/WWN addresses must be managedlocally (not by an external console) to use this command.Synopsis racadm setflexaddr [-i <slot#> <state>][-f <fabricName> <state>]<slot#> = 1 to 4<fabricName> = A<state> = 0 or 1where 0 is disable and 1 is enable.Input • -i <slot#> <state> — Enables or disables FlexAddress for the specified slot.• -f <fabricName> <state> — Enables or disables FlexAddress for the specifiedfabric.Example • racadm setflexaddr -i 1 0Slot 1 FlexAddress state set successfully• racadm setflexaddr -f A 1Fabric A FlexAddress state set successfully• racadm setflexaddr -f idrac 1setledDescription Sets the state (blinking or not blinking) of the LED on the specified module.To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administratorprivilege on CMC. To enable the servers to blink or unblink, you must have the ServerAdministrator or Debug Administrator privilege on CMC.Synopsis racadm setled -m <module> -l <ledState>Input • -m <module> - Specifies the module whose LED you want to configure.<module> can be one of the following:— server-n, wheren=1–4— switch-n, where n=1— cmc-active— chassis• -l <ledstate> - Specifies whether the LED should blink.<ledstate> can be one of the following:– 0 — no blinking– 1 — blinkingExample • racadm setled -m server-1 -1 1LED state was set successfully.NOTE: The setled command generates an error when used on the extension slot of amulti-slot server.84