support.dell.com PowerVault 56F 16-Port Fibre Channel Switch Commands 4-35 #The interfaceShow command displays FSPF interface information. This includesstatic information about the port (for example, variables allocated even when a port isdown), and “neighbor” information which includes variables associated with theremote switch connected to the port. An FSPF interface corresponds to an E_Port.The static information fields are described in Table 4-21. Neighbor information fieldsare described in Table 4-22.With no parameters, it shows the information for all switch interfaces. The commandsyntax is interfaceShow #>.( 3 %% !!'' % version The version of the FSPF protocoldomainID The local switch’s domain IDisl_ports A bitmap field that shows all local switch E_PortsstartTime The time the FSPF started, in milliseconds from bootother The other fields represent internal FSPF variables( % !!'' % idbP The current neighbor state; its value must be NB_ST_FULLfor the ISL to forward frames to the adjacent switch; othervalues may be transitory; however if a value is retained formore than ten seconds, contact Dell for technical assistancenghbP Neighbor capabilities has a value of 0ifNo The port number; it should be identical to the value specifiedin the command linecost The cost of sending a frame over the ISL connected to thisport; the value 1000 indicates a 1-gigabits per second (Gbps)linkdelay The conventional delay incurred by a frame transmitted onthis ISL; it is required by the FSPF protocol, and is a fixedvaluelastScn Last State Change Notification (SCN) received on thisinterfacelastScnTime Time the last SCN was receivedupCount The number of times this interface initialized (the transitionnumber from an offline to E_Port state)