Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Storage Center Hardware Components
- Storage Center Architecture Options
- Communication Links
- Front End
- SC8000 Controller
- SC8000 Front-Panel Features and Indicators
- SC8000 Back-Panel Features and Indicators
- SC280 SAS Enclosures
- SC280 Enclosure Front Panel Features and Indicators
- SC280 Drawer Front-Panel Features and Indicators
- SC280 Back-Panel Features and Indicators
- SC280 EMM Features and Indicators
- SC280 Power Supply Unit Features and Indicators
- Fan Module Features and Indicators
- SC280 Enterprise Plus Drives
- SC280 Drive Numbering
- SC200/220 Front-Panel Features and Indicators
- SC200/220 Back-Panel Features and Indicators
- SC200/220 EMM Features and Indicators
- SC200/220 Enterprise Plus Drives
- SC200/220 Drive Numbering
- EN-SASx6x12/24 Enclosures
- EN-SASx6x12/24 Back-Panel Features and Indicators
- EN-SASx6x12/24 SBB Module Features and Indicators
- EN-SASx6x12/24 Standard SAS Drives
- EN-SASx6x12/24 Drive Numbering
- Install the Hardware
- Gather Required Materials
- General Safety Precautions
- Electrostatic Discharge Precautions
- Install IO Cards the Controller(s)
- Install IO Cards
- Close the Cover
- Label the Controllers
- Mount the Hardware in a Rack
- U Enclosures
- Install Drives in SC280 Enclosures
- Install Drives in EN-SASx6x12/24 Enclosures
- Installing 2.5" Drives
- Install Enterprise Plus Drives in SC200/220 Enclosures
- Connect the Back End
- SC8000 SAS Port Types
- Connect the Controllers with Ethernet
- Connect the Controllers with SAS
- Connect SC200/SC220 Enclosures
- Single Controller, Single Enclosure, Low Profile SAS
- Single Controller, Single Enclosure
- Single Controller, Four Enclosures, Single Chain, Low Profile SAS
- Single Controller, Four Enclosures, Single Chain
- Single Controller, Four Enclosures, Two IO Cards, Two Chains, Low Profile SAS
- Single Controller, Four Enclosures, Two IO Cards, Two Chains
- Dual Controllers, One Enclosure, Single Chain, Low Profile SAS
- Dual Controllers, One Enclosure, Single Chain
- Dual Controllers, Two Enclosures, Single Chain, Low Profile SAS
- Dual Controllers, Two Enclosures, Single Chain
- Dual Controllers, Four Enclosures, Two Chains, Low Profile SAS
- Dual Controllers, Four Enclosures, Two Chains
- Dual Controllers, Eight Enclosures, Two Chains
- Connect SC280 Enclosures
- Single Controller, Single SC280 Enclosure
- Single Controller, Two SC280 Enclosures
- Dual Controller, Single SC280 Enclosure
- Dual Controller, Two SC280 Enclosures
- Dual Controllers, Two SC280 and Two SC200/SC220 Enclosures, Two Chains
- Connect EN-SASx6x12/24 Enclosures
- Dual Controllers, Four Enclosures, Single Chain
- Label the Back-End Cables
- Connect the Front End
- Multipath IO
- Virtual Port Mode
- Legacy Mode
- Failover Behavior for Legacy Mode and Virtual Port Mode
- Fibre Channel Zoning
- Connect the Front End for a Single-Controller Storage Center
- Connect Servers to a Single Controller with Redundancy
- Connect the Front End for a Dual-Controller Storage Center
- Connect iSCSI Servers
- Label the Front-End Cables
- Set up the Storage Center Software
- Required Materials
- Connect the Ethernet Management and iDRAC Interfaces
- Connect Dual-Controller Management Ports
- Turn on the Hardware
- Set Controller IP Addresses
- Manage the iDRAC IP Address
- Verify Software Support for Enclosures
- Start the Storage Center Startup Wizard
- Complete the Startup Wizard
- Load the License File
- Create a Disk Folder
- Add a Controller
- Set the Time
- Set the System IP Address
- Configure a Key Management Server
- Configure SMTP
- Select Update Option
- Set Admin Account
- Configure IO Cards
- Configure Ports
- Generate SSL Certificate
- Label SC200 and SC220 Enclosures
- Perform Post-Setup Tasks
- Test Connectivity and Failover
- Clean up Test Volumes
- Change Administrative Passwords
- Configure a Phone Home Proxy
- Check for Storage Center Updates
- A Adding or Removing an Enclosure
- Adding SC280 Enclosures
- Adding to an Existing SC280 Enclosure Chain
- Adding SC200/220 Enclosures
- Adding to an Existing SAS Enclosure Chain
- Adding a Second SAS Enclosure, Second Chain
- Removing Enclosures
- Remove an SC200/SC220 Enclosure
- B Troubleshooting
- Troubleshooting Licenses
|
Dell Compellent 205B TroubleshootingThis appendix contains troubleshooting steps for common problems.ContentsTroubleshooting the Serial Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205Troubleshooting Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205Troubleshooting Licenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206Troubleshooting Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206Troubleshooting the Serial ConnectionTroubleshooting EnclosuresIssue Possible Reason SolutionUnable to connect to acontroller with a serialconnectionCommunication problems. • Reseat or replace cables.• Verify the telnet settings.Issue Possible Reason SolutionNo Disks Found by StartupWizard:No disks could be foundattached to this DellCompellent Storage Center.Need to update software and/orfirmware to use attachedenclosure.1 Click Quit.2 Check for Storage Center Updates on page 172.3 Complete the Startup Wizard on page 129.Enclosure firmware updatefailsCabling is not redundant. 1 Check the back‐end cabling and ensure thatredundant connections are used.See SAS Redundancy on page 55 for moreinformation.Expected Disks and/orEnclosures are MissingNeed to update software and/orfirmware to use attachedenclosure and/or drives.1 Check the back‐end cabling and enclosure’spower state.2 Check for Storage Center Updates on page 172.
PreviousNext |