Chapter 16 PLC Function Applications│CP200016-816-3-2 I/O device explanationInput devices:SerialNo.X0 X1 X2 X3 X4 X5 X6 X7 X10 X11 X12 X13 X14 X15 X16 X171 FWD REV MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI82 MI10 MI11 MI12 MI13 MI14 MI153 MI10 MI11 MI12 MI131: Control I/O2: Expansion card EMC-D611A (D1022=4)3: Expansion card EMC-D42A (D1022=5)Output devices:SerialNo. Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y171 RY1 RY2 RY32 MO10 MO113 RY10 RY11 RY12 RY13 RY14 RY151: Control I/O2: Expansion card EMC-D42A (D1022=5)3: Expansion card EMC-R6AA (D1022=6)16-3-3 Installation WPLSoftSee Delta's website for WPLSoft editing software:http://www.delta.com.tw/product/em/download/download_main.asp?act=3&pid=3&cid=1&tpid=316-3-4 Program writingAfter completing installation, the WPLSoft program will be installed in the designated subfolder"C:\Program Files\Delta Industrial Automation\WPLSoft x.xx." The editing software can now be runby clicking on the WPL icon using the mouse.