4Instruction Book IB02707112EAugust 201550/75VCPW-VSRBreaker To Vacuum Starter Replacement UnitEATON CORPORATION www.eaton.comSECTION 1: INTRODUCTIONThe purpose of this book is to provide instructions for receivingand handling, storage, installation, operation and maintenance ofthe Westinghouse* type VCP-W Medium Voltage Vacuum StarterReplacement (also referred to as VSR-Series). The Vacuum StarterReplacement units are designed to be used in existing type VCP-Wmetalclad switchgear and provide equal of superior electrical andmechanical performance as compared to the design ratings of theoriginal power circuit breakers when switching motors. VSR-SeriesUnits provide reliable control, protection and performance, with easeof handling and maintenance. Like ratings are interchangeable witheach other.This book is intended to be used in conjunction with the technicalinformation provided with the original equipment order whichincludes, but is not limited to electrical control schematics and wiringdiagrams, outline diagrams, installation plans, and procedures forinstallation and maintenance of accessory items.Satisfactory performance is dependant upon proper application,correct installation, and adequate maintenance. It is stronglyrecommended that this instruction book be carefully read andfollowed in order to realize optimum performance and long useful lifeof the unit.Note:N * Westinghouse may also be designated as Cutler-Hammer and/orEaton. WARNINGSATISFACTORY PERFORMANCE OF THESE UNITS ARE CONTINGENTUPON PROPER APPLICATION, CORRECT INSTALLATION AND ADEQUATEMAINTENANCE. THIS INSTRUCTION BOOK MUST BE CAREFULLY READAND FOLLOWED IN ORDER TO OBTAIN OPTIMUM PERFORMANCE FORLONG USEFUL LIFE OF THE UNITS. IT IS FURTHER RECOMMENDED THATTHE INSTALLATION BE PERFORMED BY A EATON CORPORATION TRAINEDENGINEER OR TECHNICIAN.VSR-SERIES UNITS ARE PROTECTIVE DEVICES, AS SUCH, THEY AREMAXIMUM RATED DEVICES. THEREFORE, THEY SHOULD NOT UNDER ANYCIRCUMSTANCE BE APPLIED OUTSIDE THEIR NAMEPLATE RATINGS.ALL POSSIBLE CONTINGENCIES WHICH MIGHT ARISE DURINGINSTALLATION, OPERATION, OR MAINTENANCE, AND ALL DETAILSAND VARIATIONS OF THIS EQUIPMENT ARE NOT COVERED BY THESEINSTRUCTIONS. IF FURTHER INFORMATION IS DESIRED BY THEPURCHASER REGARDING A PARTICULAR INSTALLATION, OPERATION, ORMAINTENANCE OF THIS EQUIPMENT, THE LOCAL EATON’S ELECTRICALSERVICES & SYSTEMS REPRESENTATIVE SHOULD BE CONTACTED.1.1 AVAILABLE VCPW-VSR UNITSRefer to Table 1.1Tablt 1. VCPW-VSR Availabilioy and InotrchangtabilioyOriginal Breaker Type MV-VSR BreakerTo Vacuum StarterReplacement UnitBILkVRated MaximumkVContactor Amps Maximum FuseRating AmpsFused ShortCircuit RatingkAMaximumContinuousAmps50VCP-W 250-1200A 50VCPW-VSR-250-290A 60 4.76 400 230 50 23050VCP-W 250-1200A 50VCPW-VSR-250-390A 60 4.76 400 390 50 39050VCP-W 350-1200A 50VCPW-VSR-350-290A 60 4.76 400 230 50 23050VCP-W 350-1200A 50VCPW-VSR-350-390A 60 4.76 400 390 50 39075VCP-W 500-1200A 75VCPW-VSR-500-290A 60 7.2 400 230 50 23075VCP-W 500-1200A 75VCPW-VSR-500-390A 60 7.2 400 390 50 390 PreviousNext |