Eaton Crouse-Hinds EVHF106 Series Installation & Maintenance Information
IF 1700 • 02/14 Copyright © 2014 Eaton’s Crouse-Hinds Business Page 1EVHF106 Series Portable LightingFixture for Hazardous LocationsInstallation & Maintenance InformationSAVE THESE INSTRUCTIONS FOR FUTURE REFERENCEIF 1700APPLICATIONThe EVHF106 S714 portable hand lamp is used toprovide task lighting in hazardous (classified) locations.When properly installed, EVHF106 hand lamps aresuitable for use in Class I, Groups C, D (26 wattsmaximum) and Class II, Group G (26 watts maximum)locations as defined by the National Electrical Code®.The standard EVHF106 S714 hand lamp is designed foruse with #16/3 type SOOW portable cord only. Portablecord to be: 90ºC 600 Volt UL/CSA, current Amps13. Cord size 0.390-0.625. Cord is to be supplied byinstaller. Cord to be rated “Extra Hard Usage” (perNEC501.140(B)(1).Note: This portable lighting fixture include a 26Wcompact fluorescent lamp (Type: Energy Saver T2,Model: EL-md T2 26W) by Phillips.DISASSEmbLy FOR wIRINg & LAmPINg1. Loosen handle locking set screw (1) and unscrewblack plastic handle assembly (2) from guard andglobe assembly (3). DO NOT disassemble themetal ring and glass globe.2. Loosen cord clamp (7) from connector housing (8)by loosening the two attachment screws (9).3. Remove locking screw (10) that holds the handleand connector housing together. Save this lockingscrew for later replacement.4. Unscrew the connector housing from the handle.wIRINg AND REASSEmbLy1. Insert end of #16/3 type SOOW cord (11) throughcord support bushing (6), connector housing (8),spacer (5) and cord grip assembly (4). (Loosen 4screws on cord grip assembly just short of removaland push cord through grips approximately 6inches).2. Remove outer covering of cord 7/8” and strip endof each wire in the cable 3/8” for connections tothe three pressure connectors (12) as follows:a. Attach grounding wire (green) to terminal marked“G” (green colored connector).b. Attach grounded wire (white) to terminal marked“W” (nickel plated connector).c. Attach third wire (black) to the remaining terminal(copper). Make certain there are no loose strandsof wire outside the connectors.3. Slide cord grip assembly toward handle to engagelocating notches in handle.wARNINgDO NOT disassemble the cast metal guard/glassglobe assembly. Disassembly of the globe portion ofthe hand lamp is limited to removing the guard/globeassembly from the black plastic handle assembly.CAUTIONUse only #16/3 type SOOW portable cord withEVHF106 S714 hand lamp.4. Make sure cord insulating jacket extends fullythrough cord grip assembly (push down on cord)and tighten 4 screws in cord grip assembly. Ifthe 4 screws were removed during disassembly,be sure the indicating arrows are properly alignedwhen reassembling and tightening.5. Slide spacer against cord grip assembly.6. A silicone base lubricant has been applied at thefactory on “O” ring and handle threads of blackplastic handle assembly (2). Reapply if required.7. Make sure cord grip assembly is properlypositioned on locating notches in handle. Threadconnector housing (8) fully over handle.8. Replace locking screw (10) in handle.9. Slide cord support bushing (6) tight against spacer,protruding through connector housing.10. Fully tighten screws (9) on cord clamp (7), ontoconnector housing (8).11. Install lamp in lamp holder (See nameplate forproper lamp designation and wattage) and securelytighten lamp into place.12. Replace guard and globe assembly onto handleuntil fully and completely tightened.13. Securely tighten the handle locking set screw.mAINTENANCE1. The glass globe should be cleaned on a regularbasis to maintain optimum lighting performance.2. At the time of cleaning, inspect globe and guardfor tightness. If loose, retighten and lock with setscrew.3. Check cord for abrasion, cuts, or breaks. Replace ifnecessary.4. Perform visual, electrical, and mechanicalinspections on a regular basis. This should bedetermined by the environment and frequencyof use; however, it is recommended that acheck should be made at lease once a year. Werecommend an Electrical Preventative MaintenanceProgram as described in the National FireProtection Association Bulletin NFPA No. 70B.Note: For this portable lighting fixture use Phillipscompact fluorescent lamps type Energy SaverT2. Models: EL-md T2 23W & EL-md T2 26W) byPhillips.All statements, technical information and recommendations contained herein are based on information and tests we believe to bereliable. The accuracy or completeness thereof are not guaranteed. In accordance with Crouse-Hinds “Terms and Conditions of Sale,”and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended useand assumes all risk and liability whatsoever in connection therewith.Eaton’s Crouse-Hinds Business IF 17001201 Wolf Street Syracuse, New York 13208 • USA Revision 1Copyright © 2014 New 02/14wARNINgAll electrical power must be turned off before andduring maintenance.wARNINgGlobe is tempered explosionproof glass and ifscratched or chipped it must be immediatelyreplaced to prevent equipment and/or personaldamage or injury.CAUTIONGlobe/guard assembly is factory sealed and must notbe disturbed. For globe replacement, please contactyour Crouse-Hinds ECM Sales Representative or theSales/Service Department in Syracuse.globe &guardAssemblyHandleLocking SetScrewLockingScrew forConnectorHousingHandleAssembly3 PressureConnectorsConnectorHousingCordClampScrewsCordSupportCordCord gripAssembly Spacer1.2.8.9.10.3.4. 5.6.7.12.11. |
Related manuals for Eaton Crouse-Hinds EVH2625E
Eaton Crouse-Hinds Champ DMVFB Auxiliary Series Installation & Maintenance Information
Eaton PVM Series Installation & Maintenance Information
Eaton Champ MLLA M2 Series Installation & Maintenance Information
Eaton Pauluhn Meridian FDA Series Installation & Maintenance Information
Eaton ELPSM22 Installation & Maintenance Information
Eaton Crouse-Hinds Series Instruction Manual
Eaton CROUSE-HINDS Series Instruction Manual
Eaton Crouse-Hinds Series Instruction Manual
Eaton Crouse-Hinds Series Instruction Manual
Eaton CROUSE-HINDS Series Operating Instruction
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine