Eaton ELPSM22 Installation & Maintenance Information
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCEIF 1875EMERGENCY LIGHTING PRODUCTSELPSM22 system, ELPSM22 EXS/EXD system, ELPSM20 power supply,EVLAM2 luminaireInstallation & maintenance information! IMPORTANTEmergency lighting system should be installed, inspected, operated andmaintained by qualified and competent personnel.APPLICATIONThe ELPSM22 emergency lighting system is designed to automatically provideillumination to designated areas during failure or interruption of power to the normallighting system. The ELPSM22 is factory assembled and wired, and consists of one(1) ELPSM20 power supply and two (2) EVLAM2 luminaires.When properly installed, the following raintight ELPSM2 emergency lighting systemsare UL and cUL Listed for use in:• ELPSM20 power supply – Class I, Division 1, Groups B, C, D• ELPSM22 – Class I, Division 1, Groups B, C, D• Wet locations, Type 3R• Ambient temperature = 0°C to 40°C• Operating temperature code = T5• Maximum mounting height = 9.3 ft.Exit signs are not UL/cUL Listed:• ELPSM22 (EXS/EXD)• ELPSM2 EVI EMERGENCY LIGHTING EQUIPMENT (EXIT SIGN)• ELPSM2 EVA GB EMERGENCY LIGHTING EQUIPMENT (GB [Group B] EXITSIGN)All ELPSM2 emergency lighting systems without exit signs are suitable for use inClass II, Division 1, Groups E, F, G and simultaneous presence hazardous (classified)areas as defined by the National Electrical Code®.The ELPSM20 power supply consists of a battery supply and battery rechargingsystem housed inside a hazardous area enclosure with all the circuitry to automaticallyturn on emergency DC lighting equipment when the normal power supply fails. Apilot light indicates when normal power is being supplied to the unit. A push-to-testpushbutton switch is provided for periodic testing of the unit.Detail indication logic is given below:Immediately after supply power is initiated, the indicating lamp will blink/pulse toindicate that the unit is charging. Once installed with supply power, the ELPSM2requires 15 hours to charge the battery. Once the unit has completed charging, theindicating light will stop blinking and go to steady. Every six months, the unit willautomatically perform a 90 minute battery discharge test.At the completion of the test, if it is determined not to have met the 90 minuterequirement, the indicating lamp will display circuit failure (3 blinks). At any time, if thebattery connection is not adequate, the indicating lamp will display a battery failure (2blinks).The EVLAM2 luminaire is a factory sealed assembly housing a single LED lamp/reflector light source. ELPSM2 EVI and ELPSM2 EVA GB exit signs are factory sealedwith a single LED light source. Lamps are included with all equipment.Status indication Status description Status definitionNo light AC power removed from circuit* Steady light (no blinks) Fully charged or test in process* - * Light blinks once Battery charging**-** Light blinks twice Battery failure***-*** Light blinks three times Circuit failure****-**** Light blinks four times Lamp failureRATINGSIF 1875 • 03/19 Copyright® 2019, Eaton’s Crouse-Hinds Division Page 1! WARNINGTo avoid personal injury, electric shock and equipment failure:1. Do not use this equipment for other than intended use.2. The use of accessory equipment not recommended by the manufacturermay cause an unsafe condition.3. Electrical power must be turned OFF and the battery must bedisconnected using the battery disconnect switch (if provided) before andduring installation and maintenance.4. Equipment should be mounted in locations where it will not readily besubjected to tampering by unauthorized personnel.5. Do not mount near gas or electric heaters.6. In Class I areas, install and seal all equipment in accordance with theNational Electrical Code articles pertaining to hazardous (classified)locations, plus any other applicable codes.7. Install only wiring systems with an equipment grounding conductor (whichmay be the conduit system) to supply the ELPSM2.8. For safety in maintenance and servicing, a designated battery disconnectswitch and a designated supply circuit disconnect switch must be installed.A main branch disconnect is suitable for disconnecting supply circuit.9. Free installation area of hazardous atmospheres before wiring.10. Observe all battery handling precautions contained herein.11. Hammers or prying tools must not be allowed to damage the flat jointsurfaces of the ELPSM20 power supply housing. Do not handle coversroughly, or place them on surfaces that might damage or scratch the flatjoint surfaces.Table 1Power supplyInput • 120-277 VAC, 50/60 Hz• 3.81 watts maximumOutput • 12 VDC; 0.33 amperes maximum• 4 watts maximum for 1 ½ hoursLamp fixturesLamp model: LEDTronicsLEDG4BPF-1.5W-XIW-012V(G4 2-pin base, 3000K)• Input = 12 VDC, 1.5WLamp model: Westinghouse33184 (G4 2-pin base, 3000K) • Input = 12 VDC, 1.5WSTORAGE ENVIRONMENTThe ELPSM2 luminaire and accessories must be stored in an ambient temperaturefrom 0°C to +40°C. This includes units that have already been installed and may bepowered down for extended periods of time (i.e. facility maintenance shutdowns).Store in a dry location.IMPORTANT SAFEGUARDS – READ AND FOLLOW ALL SAFETY INSTRUCTIONS |
Related manuals for Eaton ELPSM20
Eaton PVM Series Installation & Maintenance Information
Eaton Champ MLLA M2 Series Installation & Maintenance Information
Eaton Pauluhn Meridian FDA Series Installation & Maintenance Information
Eaton Crouse-Hinds EVHF106 Series Installation & Maintenance Information
Eaton Crouse-Hinds Champ DMVFB Auxiliary Series Installation & Maintenance Information
Eaton Metalux Installation Instructions Manual
Eaton ILS-1100 Installation Quick Manual
Eaton Halo HD4 Installation Instructions Manual
Eaton LumaWatt Installation Instructions Manual
Eaton Metalux FPX Installation Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine