i-on16 InstallationPage 13Keep the prox reader cable clear of cablessupplying sounders or extension loudspeakers.Figure 23 shows the wiring connections at thekeypad.Figure 23. Connecting the External Prox ReaderTone Volume – All KeypadsTo adjust the volume of tones from the keypad:LouderNote: This control changes thevolume of non-alarm tones (forexample Exit/Entry tone). Thevolume of alarm tones is fixed.SofterFigure 24. Adjusting Keypad Volume.Connecting Wired Zones (KEY-KPZ01 only)The KEY-KPZ01 provides terminals for up to twozones. You must enable the zones from the InstallerMenu – Detectors/Devices – Wired Keypads – EditKeypad (keypad number) – Zones.Once the zones are enabled they occupy the zonenumbers at the top of the numbering range,depending on the address of the keypad.Keypad zone Panel zoneFSLPanel ZoneCCLKeypad 1 Zone 1 15 15 AlarmKeypad 1 Zone 2 16 15 TamperKeypad 2 Zone 1 13 13 AlarmKeypad 2 Zone 2 14 13 TamperTo select the wiring type for the keypad zones useInstaller Menu - System Options - Wired Zone Type – AllZones. Alternatively, to select the wiring type for anindividual keypad, use Installer Menu –Detectors/Devices – Wired Keypads – Edit Keypad(keypad number) – Wired Zone Type.Figure 25 shows the wiring connections for FSLzones on a KEY-KPZ01. Note that the resistancevalues shows are examples.Figure 25. Wiring FSL Zones on KEY-KPZ01Figure 26 shows the wiring connections for ClosedCircuit Loop connections to the zones on a KEY-KPZ01,Figure 26. KEY-KPZ01 CCL Zone WiringStep 3. Connect End Stationto MainsWARNING: ENSURE THAT THE MAIN SUPPLY ISDISCONNECTED AND ISOLATED BEFOREMAKING ANY MAINS CONNECTIONS. All mainselectrical connections must be carried out by aqualified electrician and must comply with thecurrent local regulations (e.g. IEE).Mains CablingMake sure that the mains supply cable does not runvertically behind the aerials within the end stationcase.Figure 27. Mains CablingKEY-KPZ01Zone 0Zone 1 2K2 EOL4K7Alarm contactsTamper contacts2K2 EOL4K7Alarm contactsTamper contacts100 OhmsTamper Zone 1Alarm Zone 1KEY-KPZ01>1m >1m