48EnglishInstallationThis appliance is designed for domestic cooking only. Usefor any other purpose could invalidate any warranty orliability claim.Before installation, ensure that cooker is suitable for yourgas type and supply voltage. See the appliance data badge.Check the data badge to determine which gas the cooker isset for.ConversionThis appliance is supplied as: -G 20 20millibar CAT II2E3+A conversion kit for other gases is supplied with thecooker. If the appliance is to be converted to another gaswe recommend that this is done before installation. Seethe Conversion Instructions packed with the conversionkit. After converting the appliance please attach the GasConversion sticker over the appropriate area of the databadge, this will identify the gas type the appliance is nowset for.Safety Requirements/RegulationsThis appliance must be installed by a competent person.The installation must comply with the relevant regulationsand also the local electricity supply company requirements.Read the instructions before installing or using thisappliance.In your own interest and that of safety, it is law that all gasappliances be installed by competent persons. Failure toinstall the appliance correctly could invalidate any warrantyor liability claims and lead to prosecution.Before installation, ensure that cooker is suitable for yourgas type and supply voltage. See the data badge.Install in a well-ventilated space.Provision of VentilationThis appliance is not connected to a combustion productsevacuation device. It shall be installed and connected inaccordance with current installation regulations. Particularattention shall be given to the relevant requirementsregarding ventilation.Local regulations regarding ventilation must be adhered tobut as a minimum:All rooms require an openable window or equivalent, whilesome rooms require a permanent vent in addition to theopenable window. The cooker should not be installed in abedsitting room with volume less than 20m3. If it is installedin a room of volume less than 5m3 an air vent of effectivearea 100cm2 is required; if it is installed in a room of volumebetween 5m3 and 10m3, an air vent of effective area 50cm2is required; while if the volume exceeds 11m3, no air ventis required. However, if the room has a door that opensdirectly to the outside, no air vent is required even when theroom volume is between 5m3 and 10m3. If there are otherfuel burning appliances in the same room, more ventilationmay be required.Location of HotplateThe hotplate may be installed in a kitchen/kitchen diner butNOT in a room containing a bath or shower.NOTE:An appliance for use on LPG shall not be installed ina room or internal space below ground level. e.g. in abasement.This appliance is designed for domestic cooking only.Use for any other purpose could invalidate any warrantyor liability claim.Positioning the CookerThe diagrams below show the minimum recommendeddistance from the cooker to nearby surfaces.The cooker should not be placed on a base.The hotplate surround should be level with, or above, anyadjacent work surface. Above hotplate level a gap of 75mmshould be left between each side of the cooker and anyadjacent vertical surface.For non-combustible surfaces (such as unpainted metal orceramic tiles) this can be reduced to 25mm.A minimum space of 650mm is required between the top ofthe hotplate and a horizontal combustible surface.*Any cooker hood should be installed in accordance withthe hood man u facturer’s instructions.Surfaces of furniture and walls at the sides and rear ofthe appliance should be heat, splash and steam resistant.Certain types of vinyl or laminate kitchen furniture are