3911. Technical DataThis cooker is designed for use on Natural Gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is packed with thecooker.INSTALLER: Please leave these instructions with the user.DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.COUNTRY OF DESTINATION: Australia.ConnectionsGas (Rp ½ at rear right-hand side) ElectricNatural gas 1 kPa 230 V 50 HzPropane 2.75 kPaSee the appliance badge for test pressures.DimensionsOverall height minimum 900 mm maximum 925 mmOverall width 900 mmOverall depth 600 mm (to fascia); 650 mm (over handles)Minimum space above the hotplate 650 mmRefer to 'Positioning the Cooker'.RatingsNatural Gas 1.0 kPa LP Gas 2.54 kPaHotplate Injector Bypass Injector BypassWok burner 15.2 MJh-1 internal 112 90 15.0 MJh-1 internal 66 54external 164 external 91Large Burner 12.3 MJh-1 165 80 12.0 MJh -1 89 41Medium Burners 6.2 MJh-1 115 56 6.2 MJh-1 67 33Small Burner 3.7 MJh-1 92 48 3.3 MJh-1 45 25Oven 9.5 MJh-1 160 70 9.5 MJh-1 87 79Grill 10 MJh-1 280 77 10 MJh -1 100 96Right-hand Tall Oven Forced Air ConvectionMaximum power output @ 230 V 50 Hz 2.5 kWEnergy efficiency class on a scale of A (more efficient) to G (less efficient) AEnergy consumption based on standard load 0.99 kWhUsable volume (litres) 66Size LargeTime to cook standard load 49 minutesSurface area of the grid 790 cm2Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 2.6 kW.ArtNo.105-0008 - Technical data - 90 induction - Elan