15Table 8 - Performa 960 FA Level II Programming ParametersParameter Range of Values MinimumIncrements Default Units of Measure NotesName DescriptionP6 Refill controller 1 to 99 1 33 Must be set to 46 for Performa 960FA operationP7 Regenerant drawvalue 1 to 99 1 25 Select Regenerant Draw value fromTable 9 and enter that number.P8 Not used NA NA NA NA NAP9 Backwash time 3 to 30 1 14 Minutes Skip this parameter to accept thedefault or enter a value.P10 Slow Rinse time 8 to 125 1 40 Minutes Skip this parameter to accept thedefault or enter a value.P11 Fast Rinse time 2 to 19 1 4 Minutes Skip this parameter to accept thedefault or enter a value.P12 Units of measure 0 to 1 1 00 = U.S., 1 = Metric. Skip thisparameter to accept U.S. or enter 1for Metric.P13 Clock mode 0 to 1 1 00 = 12-hour clock, 1 = 24-hourclock. Skip this parameter for a 12-hour clock or enter 1 for a24-hour clock.P14 Calendaroverride 0 to 30 1 0 Days0 = no calendar override. Skip thisparameter for no calendar overrideor enter a value.P15 Reserve type 0 to 3 1 00 = variable reserve, 1 = fixedreserve, 2 = variable reserve withimmediate regen, 3 = fixed reservewith immediate regen. Skip thisparameter to accept the default orenter a different reserve type.P16Fixed reservecapacity or initialaverage value0 to 70 1 30 Percent of capacityDescription depends on the valueentered for P15. Skip thisparameter to accept the default orenter a different value.P17 Operation type 0 to 2 1 2 2 = 5 cycle Cocurrent conditionerP18Regen. Dosage/Capacity changelock out0 to 1 1 00 = none, 1 = Regenerant Dosage/Capacity change locked out. Skipthis parameter to accept thedefault or enter 1 to lock outRegenerant Dosage/Capacitychange.P19 Factory defaults 0 to 3 1 99 Loads in factory default values. Donot change this parameter.