9Table 3 - Level II Programming ParametersParameterName Description Range of Values MinimumIncrements Default Units ofMeasure NotesP6 Refill controller 1 to 99 1 33 Enter the value molded into theend of the refill controller.P7 Regenerantdraw value 1 to 99 1 25 Select number from Table 4 andenter that number.P8 Not used NA NA NA NA NAP9 Backwash time 3 to 30 1 14 Minutes Skip this parameter to accept thedefault or enter a value.P10 Slow rinse time 8 to 125 1 40 Minutes Skip this parameter to accept thedefault or enter a value.P11 Fast rinse time 2 to 19 1 4 Minutes Skip this parameter to accept thedefault or enter a value.P12 Units of Measure 0 to 1 1 00 = U.S., 1 = metric. Skip thisparameter to accept U.S. or enter1 for metric.P13 Clock mode 0 to 1 1 00 = 12-hour clock.1 = 24-hour clock. Skip thisparameter for a 12-hour clock orenter 1 for a 24-hour clock.P14 Calendaroverride 0 to 30 1 0 Days0 = no calendar override. Skip thisparameter for no calendaroverride or enter a value.P15 Reserve type 0 to 3 1 00 = variable reserve, 1 = fixedreserve, 2 = variable reserve withimmediate regen,3 = fixed reserve with immediateregen. Skip this parameter toaccept the default or enter adifferent reserve type.P16Fixed reservecapacity or initialaverage value0 to 70 1 30 Percent ofcapacityDescription depends on the valueentered for P15. Skip thisparameter to accept the default orenter a different value.P17 Operation type 0 to 2 1 2 2 = 5-cyclecocurrent conditioner.P18 Salt/capacitychange lockout 0 to 1 1 00 = none, 1 = salt/capacity changelocked out. Skip this parameter toaccept the default or enter 1 tolock out salt/capacity change.P19 Factory defaults 1 99Loads in a set of default values.Refer to the Special Notes forLevel II Parameters section in thismanual. Do Not Change.