GE Multilin D60 Line Distance Protection System B-25APPENDIX B B.4 MEMORY MAPPINGB3E39 Field Shared Output 1 Channel Dest 1 0 to 15 --- 1 F001 13E3A Field Shared Output 1 Unit Dest 2 0 to 8 --- 1 F256 0 (none)3E3B Field Shared Output 1 Channel Dest 2 1 to 15 --- 1 F001 13E3C Field Shared Output 1 Events 0 to 1 --- 1 F102 1 (Enabled)3E3D ...Repeated for Field Shared Output 23E4A ...Repeated for Field Shared Output 33E57 ...Repeated for Field Shared Output 43E64 ...Repeated for Field Shared Output 53E71 ...Repeated for Field Shared Output 63E7E ...Repeated for Field Shared Output 73E8B ...Repeated for Field Shared Output 83E98 ...Repeated for Field Shared Output 93EA5 ...Repeated for Field Shared Output 103EB2 ...Repeated for Field Shared Output 113EBF ...Repeated for Field Shared Output 123ECC ...Repeated for Field Shared Output 133ED9 ...Repeated for Field Shared Output 143EE6 ...Repeated for Field Shared Output 153EF3 ...Repeated for Field Shared Output 16Field Unit RTDs (Read/Write Setting) (8 modules)3F00 Field Unit RTD 1Name 0 to 1 --- 1 F205 "RTD 1"3F06 Field Unit RTD 1 Origin 0 to 1 --- 1 F205 "RTD 1"3F07 Field Unit RTD 1 Type 0 to 2 --- 1 F259 0 (100 OhmNickel)3F08 ...Repeated for Field Unit RTD 23F10 ...Repeated for Field Unit RTD 33F18 ...Repeated for Field Unit RTD 43F20 ...Repeated for Field Unit RTD 53F28 ...Repeated for Field Unit RTD 63F30 ...Repeated for Field Unit RTD 73F38 ...Repeated for Field Unit RTD 8Field Unit Transducers (Read/Write Setting) (8 modules)3F40 Field Unit Transducer 1 Name 0 to 1 --- 1 F205 "TRD 1"3F46 Field Unit Transducer 1 Origin 0 to 24 --- 1 F53 0 (none)3F47 Field Unit Transducer 1 Range 0 to 9 --- 1 F246 6 (0...20mA)3F48 Field Unit Transducer 1 Min Value -9999.999 to 9999.999 --- 0.01 F004 03F4A Field Unit Transducer 1 Max Value -9999.999 to 9999.999 --- 0.001 F004 1000003F4C Field Unit Transducer 1 Units --- --- --- F206 (none)3F4F ...Repeated for Field Unit Transducer 23F5E ...Repeated for Field Unit Transducer 33F6D ...Repeated for Field Unit Transducer 43F7C ...Repeated for Field Unit Transducer 53F8B ...Repeated for Field Unit Transducer 63F9A ...Repeated for Field Unit Transducer 73FA9 ...Repeated for Field Unit Transducer 8Field Unit Identifiers (Read Only) (8 modules)3FB8 Attached Field Unit 1 Serial Number --- --- 1 F205 (none)3FBE Attached Filed Unit 1 Port Number --- --- 1 F001 03FBF Attached Field Unit 1 Type 0 to 3 --- 1 F243 0 (CC-05)3FC0 Field Unit 1 Status 0 to 4 --- 1 F262 0 (Disabled)3FC1 ...Repeated for Field Unit 23FCA ...Repeated for Field Unit 33FD3 ...Repeated for Field Unit 43FDC ...Repeated for Field Unit 5Table B–9: MODBUS MEMORY MAP (Sheet 17 of 72)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT