Page 35LOC PG DESCRIPTION DEFAULT PROGRAMMING DATACUSTOMIZING ZONE TYPES (GROUPS)110 28 ZONE TYPE 1 ALARM EVENT CODE 8 __ZONE TYPE 1 CHARACTERISTIC SELECTIONSegment #11 - Fire (enable for fire zone) “2 - 24 Hour (enable for non-fire 24 hour zone) “3 - Keyswitch zone “4 - Follower (enable for burg zones that are instant during non-entry times) “5 - Delay 1 zone (enable to follow Timer #1 Entry/Exit) “6 - Delay 2 zone (enable to follow Timer #2 Entry/Exit) “7 - Interior (Enable for auto bypass or stay arming) “8 - Local Only (enable if zone is not to be reported) “Segment #21 - Keypad audible on alarm “2 - Yelping siren on alarm “3 - Temporal siren on alarm “4 - Chime “5 - Bypassable “6 - Group Shunt “7 - Force armable “8 - Entry Guard “111 28Segment #31 - Reserved2 - Double End of Line Tamper zone “3 - Trouble zone (Day zone) “4 - Cross Zone “5 - Dialer Delay zone “6 - Swinger zone “7 - Restore reporting “8 - Listen-In “THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF EACH OFTHOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM TABLE 3.1, PAGE 28 TO UNDERSTAND THESE DEFAULTS.112 28 ZONE TYPE 2 ALARM EVENT CODE 2 ____113 28 ZONE TYPE 2 CHARACTERISTIC SELECT 2-125-78 _____ _____ _____114 28 ZONE TYPE 3 ALARM EVENT CODE 7 ____115 28 ZONE TYPE 3 CHARACTERISTIC SELECT 5-1245-5678 _____ _____ _____116 28 ZONE TYPE 4 ALARM EVENT CODE 5 ____117 28 ZONE TYPE 4 CHARACTERISTIC SELECT 45-125-5678 _____ _____ _____118 28 ZONE TYPE 5 ALARM EVENT CODE 5 ____119 28 ZONE TYPE 5 CHARACTERISTIC SELECT 457-125-5678 _____ _____ _____120 28 ZONE TYPE 6 ALARM EVENT CODE 4 ____121 28 ZONE TYPE 6 CHARACTERISTIC SELECT 0-1245-5678 _____ _____ _____122 28 ZONE TYPE 7 ALARM EVENT CODE 0 ____123 28 ZONE TYPE 7 CHARACTERISTIC SELECT 2-0-78 _____ _____ _____124 28 ZONE TYPE 8 ALARM EVENT CODE 1 ____125 28 ZONE TYPE 8 CHARACTERISTIC SELECT 1-13-378 _____ _____ _____126 28 ZONE TYPE 9 ALARM EVENT CODE 7 ____127 28 ZONE TYPE 9 CHARACTERISTIC SELECT 6-1245-5678 _____ _____ _____128 28 ZONE TYPE 10 ALARM EVENT CODE 2 ____129 28 ZONE TYPE 10 CHARACTERISTIC SELECT 24-5-78 _____ _____ _____130 28 ZONE TYPE 11 ALARM EVENT CODE 3 ____131 28 ZONE TYPE 11 CHARACTERISTIC SELECT 3-0-0 _____ _____ _____132 28 ZONE TYPE 12 ALARM EVENT CODE 5 ____