12 NX-6V2 ControlL 3 DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE 1 2 ........... numericalSegment 1- Dial attempts: Location 3, Segment 1 is used to enter the number of dial attempts (1 to 15 Attempts) the communicatorwill make to Phone 1 before ending the notification process. Factory default is "8" and the communicator will make eight (8) attemptsto the first number.Segment 2- Phone 1 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-6V2 to make the designatednumber of attempts to Phone 2 before setting the "Fail To Communicate" condition and stop reporting. Programming a "1" in thissegment will cause the NX-6V2 to stop trying to communicate after the designated number of attempts have been made to Phone 1. Ifa "2" is programmed in this segment, it will cause the NX-6V2 to make the dial attempts in increments of two. The first two attempts willbe made to Phone 1, the next two attempts to Phone 2, then repeating until the total number of attempts designated in Segment 1 iscompleted.REPORTING EVENTS TO PHONE NUMBER 1Phone 1 has two programming locations that are used to select which events are reported to this phone number. Location 4 is used toselect which events are reported to Phone 1. Location 5 is used to select which partitions are reported to Phone 1. If dual or splitreporting is not desired, location 4 should be used to select all events to Phone 1 and location 5 should be left at the factory default of"0". If dual or split reporting is desired, and the split is based on the event type (such as alarm, open/close, etc.), location 4 should beused to select only those events that should be reported to Phone 1 and location 5 should be left at the factory default of "0". If dual orsplit reporting is desired, and the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used toselect those partitions that should be reported to Phone 1. If no events should be reported to Phone 1, both locations should beprogrammed as "0" (disabling all options).4 EVENTS REPORTED TO PHONE 1 2 ............ feature selectSegment 1:1 = Alarms and Alarm Restores.2 = Opening and Closings.3 = Zone Bypass and Bypass Restores.4 = Zone Trouble and Trouble Restores.5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.6 = Bell Cut, Telephone Line Cut, Bell Cut Restore, Telephone Line Restore.7 = Test Reports.8 = Start and End programming, Download complete.Segment 2:1 = Zone and Box Tamper and Tamper Restore.2 = Auxiliary Power Overcurrent, Ground Fault, and Restore for both.3 = Wireless Sensor Missing and Restore.4 = Wireless Sensor Low Battery and Restore.5 = Expander Trouble and Restore.6 = Fail To Communicate.7 = Zone Activity Monitor.8 = Reserved.5 PARTITIONS REPORTED TO PHONE 1 1 ............ feature selectLocation 5 is used when events to be reported to a phone number are based upon the partition regardless of the event. If this locationis used, location 4 should be programmed as "0".Segment 1:1 = Partition 1 2 = Partition 2L 6 PROGRAMMING PHONE 2 20 .......... numericalPhone 2 is programmed in location 6. A "14" indicates the end of the phone number. Delays of four seconds can be programmed atany point in the phone number by programming a "13" in the appropriate segment. If tone dialing is desired, program a "15" in thesegment where tone dialing should begin. If the entire number should be tone dialing, program a "15" in the first segment. Program anA11" for a Ar@, and a A12" for a A#@. Caution: A call-waiting cancel on a non- call waiting line will prevent successful connection to thecentral station.L 7 ACCOUNT CODE FOR PHONE 2 6 ............ numericalThe account code sent when Phone 2 is dialed is programmed in location 7. Program a A10" in the segment immediately after the lastdigit of the account code. If the account code is 6 digits long, program all 6 segments. If this location is left unprogrammed, accountcode 1 will be used when the second phone number is dialed.