– 32 –Outlet Control Backup ThermostatThe outlet control backup thermostat is locatedon the upper, rear area of the blower housing. It isabove the outlet control thermistor and the rack drythermostat. The outlet control backup thermostatmonitors the outgoing air temperature.If the thermostat reaches a temperature beyond itsmaximum temperature rating, it will trip and disablepower to the heating elements or burner assembly.The outlet control backup thermostat opens at165°F (74°C) and will automatically reset at 155°F(68°C).To remove the outlet control backup thermostat:Remove the drum. (See1. Drum.)Lift the right side of the vapor shield and2.disconnect the 2 wires from the outlet controlbackup thermostat.Remove the Phillips-head screw that attaches3.the outlet control backup thermostat to theblower housing.Rack Dry ThermostatThe rack dry thermostat is located on the upper reararea of the blower housing. It is above the outletcontrol thermistor. The rack dry thermostat monitorsthe outgoing air temperature.If the thermostat reaches a temperature beyond itsmaximum temperature rating, it will trip and disablepower to the heating elements or rack dry Calrodelement.The rack dry thermostat opens at 130°F (54°C) andwill automatically reset at 115°F (46°C).Note: On electric models, if the drum light isactivated by selecting DRUM LIGHT on the controlpanel during the rack dry cycle, the rack dryinterlock relay will open and heater operation willstop.To remove the rack dry thermostat:Remove the drum. (See1. Drum.)Lift the right side of the vapor shield and2.disconnect the 2 wires from the rack drythermostat.Remove the 2 Phillips-head screws that attach3.the rack dry thermostat to the blower housing.Outlet ControlBackup ThermostatRack DryThermostatElectric Model ShownElectric Model Shown