Installation Preparation4For models equipped with power cord: Do not modify theplug provided with the appliance; if it will not fit the outlet,have a proper outlet installed by a qualified technician.Cabinet Preparation & Wire Routing• The wiring may enter the opening from either side, rearor the floor within the shaded area.• Cut a 1-1/2" max. dia. hole to admit the electrical cable.Cable direct connections may pass through the samehole as the drain hose and hot water line, if convenient.If cabinet wall is metal, the hole edge must be coveredwith a bushing. NOTE: Power cords with plug must passthrough a separate hole.Electrical Connection to DishwasherElectrical connection is on the right front of dishwasher.• For cable direct connections the cable must be routedas shown in Figure E. Cable must extend a minimum of24" from the rear wall.• For power cord connections, install a 3-prong groundingtype receptacle in the sink cabinet rear wall, 6" min. or18" max. from the opening, 6" to 18" above the floor.Figure EWARNINGFOR PERSONAL SAFETY: Removehouse fuse or open circuit breakerbefore beginning installation. Do notuse an extension cord or adapter plugwith this appliance.PREPARE ELECTRICAL WIRINGElectrical Requirements• This appliance must be supplied with 120V, 60 Hz., andconnected to an individual properly grounded branchcircuit, protected by a 15 or 20 ampere circuit breakeror time delay fuse.• Wiring must be 2 wire with ground and rated for 75°C(176°F).• If the electrical supply does not meet the aboverequirements, call a licensed electrician beforeproceeding.Grounding Instructions–Cable DirectThis appliance must be connected to a grounded metal,permanent wiring system, or an equipment groundingconductor must be run with the circuit conductors andbe connected to the equipment grounding terminal orlead on the appliance.Grounding Instructions–Power Cord ModelsThis appliance must be grounded. In the event of amalfunction or breakdown, grounding will reduce therisk of electric shock by providing a path of least resis-tance for electric current. This appliance is equippedwith a cord having an equipment grounding conductorand a grounding plug. The plug must be plugged into anappropriate outlet that is installed and grounded inaccordance with all local codes and ordinances.WARNINGThe improper connection of theequipment grounding conductor canresult in a risk of electric shock. Checkwith a qualified electrician or servicerepresentative if you are in doubt thatthe appliance is properly grounded.White18"6"24"from Wall3"fromCabinetAlternateReceptacleLocationGroundBlack1-1/2" Dia.Hole (Max.)18"6"ReceptacleLocationArea