B-76 T60 Transformer Protection System GE MultilinB.4 MEMORY MAPPING APPENDIX BBF120ENUMERATION: DISTANCE SHAPE0 = Mho, 1 = QuadFixed at Mho in G60.F122ENUMERATION: ELEMENT INPUT SIGNAL TYPE0 = Phasor, 1 = RMSF123ENUMERATION: CT SECONDARY0 = 1 A, 1 = 5 AF124ENUMERATION: LIST OF ELEMENTSBitmask Element0 Phase Instantaneous Overcurrent 11 Phase Instantaneous Overcurrent 22 Phase Instantaneous Overcurrent 33 Phase Instantaneous Overcurrent 44 Phase Instantaneous Overcurrent 55 Phase Instantaneous Overcurrent 66 Phase Instantaneous Overcurrent 77 Phase Instantaneous Overcurrent 88 Phase Instantaneous Overcurrent 99 Phase Instantaneous Overcurrent 1010 Phase Instantaneous Overcurrent 1111 Phase Instantaneous Overcurrent 1216 Phase Time Overcurrent 117 Phase Time Overcurrent 218 Phase Time Overcurrent 319 Phase Time Overcurrent 420 Phase Time Overcurrent 521 Phase Time Overcurrent 624 Phase Directional Overcurrent 132 Neutral Instantaneous Overcurrent 133 Neutral Instantaneous Overcurrent 234 Neutral Instantaneous Overcurrent 335 Neutral Instantaneous Overcurrent 436 Neutral Instantaneous Overcurrent 537 Neutral Instantaneous Overcurrent 638 Neutral Instantaneous Overcurrent 739 Neutral Instantaneous Overcurrent 840 Neutral Instantaneous Overcurrent 941 Neutral Instantaneous Overcurrent 1042 Neutral Instantaneous Overcurrent 1143 Neutral Instantaneous Overcurrent 1248 Neutral Time Overcurrent 149 Neutral Time Overcurrent 250 Neutral Time Overcurrent 351 Neutral Time Overcurrent 452 Neutral Time Overcurrent 553 Neutral Time Overcurrent 656 Neutral Directional Overcurrent 164 Ground Instantaneous Overcurrent 165 Ground Instantaneous Overcurrent 266 Ground Instantaneous Overcurrent 367 Ground Instantaneous Overcurrent 468 Ground Instantaneous Overcurrent 569 Ground Instantaneous Overcurrent 670 Ground Instantaneous Overcurrent 771 Ground Instantaneous Overcurrent 872 Ground Instantaneous Overcurrent 973 Ground Instantaneous Overcurrent 1074 Ground Instantaneous Overcurrent 1175 Ground Instantaneous Overcurrent 1280 Ground Time Overcurrent 181 Ground Time Overcurrent 282 Ground Time Overcurrent 383 Ground Time Overcurrent 484 Ground Time Overcurrent 585 Ground Time Overcurrent 686 Restricted Ground Fault 187 Restricted Ground Fault 288 Restricted Ground Fault 389 Restricted Ground Fault 490 Restricted Ground Fault 591 Restricted Ground Fault 6140 Auxiliary Undervoltage 1141 Auxiliary Undervoltage 2142 Auxiliary Undervoltage 3144 Phase Undervoltage 1145 Phase Undervoltage 2146 Phase Undervoltage 3148 Auxiliary Overvoltage 1149 Auxiliary Overvoltage 2150 Auxiliary Overvoltage 3152 Phase Overvoltage 1156 Neutral Overvoltage 1157 Neutral Overvoltage 2158 Neutral Overvoltage 3160 Phase Distance Zone 1161 Phase Distance Zone 2162 Phase Distance Zone 3172 Ground Distance Zone 1173 Ground Distance Zone 2174 Ground Distance Zone 3180 Load Encroachment186 POTT190 Power Swing Detect202 Transformer Hottest Spot203 Transformer Aging Factor204 Transformer Loss of LifeBitmask Element