Part # P152 Rev 1 (01/13/10)Page 103 Remove the terminal block access cover4 Pass the wires though cable entrance hole5 Secure the cable connector6 Terminate the salamander wire at the terminal blockprovided (Red to L1, Black to L2 or N, Green to GRN or E)NOTE: When mounting a salamander over an existing rangein the field, an independent fussed connection must bemade though the knock out plate provided in the main backof the salamanderAssembly of Backguard/High ShelfThe back guard or high shelf will have been shippedseparately To install, put the backguard/high shelf on therear of the range, slipping the uprights into the opening oneach burner box side Fasten the upright to the burner boxside with four hex fasteners providedCode RequirementsThe Garland S/SS680 series complies with the standards CSAC22 2 no 109 – latest edition, the UL197 – latest edition andthe NSF#4 – latest edition The installation and connectionof this appliance must comply with current codes In Canada– The Canadian Electrical Code Part 1 and in the USA – TheNational Electrical CodeThe Garland SU680 series complies with the essentialrequirements of the Directives 73/23/EEC, 89/336/EEC,89/392/EEC, 93/68/EEC and the standards, EN60335,IEC801 2, IEC801 3, IEC801 4, IEC801 5, IEC801 6 andIEC801 11Electrical SupplyBefore attempting the electrical connection, the rating plateshould be checked to ensure that the equipment’s electricalcharacteristics and supply electrical characteristics agree Onranges and salamanders the supply entrance is located at therear or alternatively on the main bottom The supply terminalblock is accessible from the front The electrical supply mustbe adequate for the voltage, phase, and current marked onthe rating plateINSTALLATION continuedNOTE: A means of disconnection from the supply havinga contact separation of at least 3 mm in all poles must beincorporated in the fixed wiringThis equipment is intended to be installed with fixedpermanent wiringWARNING: This appliance must be groundedSingle And Three Phase ConnectionUnless otherwise noted, all ranges are shipped from thefactory for three phase connection Salamanders are shippedfrom the factory for single phase connection A wiringdiagram is attached to the rear of each appliance Visuallycheck all electrical connections The range is wired at thefactory as specified on the order If it is necessary to changethe phasing refer to the wiring diagramCommissioningEnsure all circuit breakers located in the lower compartmentare set to the ON (1) position1 Ensure that all controls are in the OFF position and turnon the main electrical supply2 Operate each section of the range or salamander inaccordance with the instructions given in the Use’sManual3 Check that the product functions correctly and that thevoltage supply to the unit does not drop more than 5%when all sections are operated simultaneouslyWhen the operation has been checked, hand the OPERATINGINSTRUCTIONS to the User or purchaser for retention andinstruct them in the efficient and safe operation of theappliance