Part # 4523343 Rev 2 (03/04/10) Page 73 Securely fasten the support brackets to the burner boxsides with (4) sheet metal screws providedUprightMain BodySideSheet MetalScrews (4 Req'd)Ventilation AirThe following notes are intended to give general guidanceFor detailed recommendations, refer to the applicablecode(s) in the country of destinationProper ventilation is critical for optimum performance Theideal method of ventilating open-top equipment is the useof a properly designed canopy that should extend six inches(152 mm), beyond all sides of the appliance(s) and six feet, sixinches (1981mm) above the floorA strong exhaust will create a vacuum in the room For anexhaust vent to work properly, replacement air must beequal to the amount of exhausted An imbalance betweenexhaust and replacement air can cause degradation in theappliance’s performanceAll gas burners and pilots need sufficient air to operate Largeobjects should not be placed in front of the appliance(s) thatwould obstruct the flow of air into the frontStatutory RegulationsThe installation of this appliance must be carried out bya competent person and in accordance with the relevantregulations, codes of practice and the related publications ofthe country of destinationThe installation must conform to the National Fuel Gas CodeANSI Z223 1, or latest edition, NFPA No 54 - latest edition/orlocal code to assure safe and efficient operation In Canada,the installation must comply with CSA B149 1 and localcodesGas ConnectionThe local gas authority should be consulted at theinstallation planning stage in order to establish theavailability of an adequate supply of gas and to ensurethat the meter is adequate for the required flow rate Thepipe work from the meter to the appliances must be anappropriate sizeAll fixed (non-mobile) appliances MUST be fitted withan accessible Upstream gas shut off valve as a means ofisolating the appliance for emergency shut off and forservicing A union or similar means of disconnection must beprovided between the gas-cock and the applianceA manually operable valve must be fitted to the gas supplyto the kitchen to enable it to be isolated in an emergencyWherever practical, this shall be located either outside thekitchen or near to an exit in a readily accessible positionWhere it is not practical to do this, an automatic isolationvalve system shall be fitted which can be operated from areadily accessible position near to the exitIn locations where the manual isolation valve is fitted or theautomatic system can be reset a notice MUST be postedstating:“ALL DOWNSTREAM BURNER AND PILOT VALVES MUSTBE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THESUPPLY AFTER EXTENDED SHUT OFF, PURGE BEFORERESTORING GAS ”Installation NotesBefore assembly and connection check gas supplyA The type of gas for which the unit is equipped is stampedon the data plate located behind the lower front panelConnect a unit stamped “NAT” only to natural gas;connect one stamped “PRO” only to propane gasINSTALLATION Continued