24 Document: GAR_SM_4601777 (4/16)General Information Section 1Gas Input SpecificationGas Grills, 1, 2 & 3 Platen North America - all CSA models.GASMAX INPUT(NET) PERBURNER(BTU/H)TOTAL INPUTRATING(BTU/H)INJECTORSIZESUPPLY PRESSURE(IN W.C.)BURNER MANIFOLDPRESSURE(IN W.C.)1PlatenNATURAL GAS10,00020,000 1.5mm 7.0” WC4.0” WCPROPANE 20,000 1.2mm 11.0” WC2PlatenNATURAL GAS 40,000 1.5mm 7.0” WCPROPANE 40,000 1.2mm 11.0” WC3PlatenNATURAL GAS 60,000 1.5mm 7.0” WCPROPANE 60,000 1.2mm 11.0” WCInput Specification - All CE Models.GASGROUPMAX INPUT (NET)PER BURNER (kW) TOTAL INPUT RATING (kW) INJECTORSIZE (mm)BURNERPRESSURE (mbar)FAN SPEEDSETTING (RPM)G20 2.935.86kW - (For XPE12 series)11.72kW - (For XPE24 series)17.58kW - (For XPE36 series)1.5mm 10mbar(4.0” WC)10,000G25 2.935.86kW - (For XPE12 series)11.72kW - (For XPE24 series)17.58kW - (For XPE36 series)1.5mm 13.7mbar(5.5” WC)G31 2.935.86kW - (For XPE12 series)11.72kW - (For XPE24 series)17.58kW - (For XPE36 series)1.2mm 10mbar(4.0” WC)For G31 propane gas, the unit has been set at the factory for a 37mbar supply pressure. A factory authorized servicetechnician must adjust the unit if a 30mbar supply pressure is used.COUNTRY GAS CATEGORY GAS TYPE SUPPLY PRESSURE (mbar)AT, CH, CY, CZ, DK, EE, ES, FI, FR, GB, GR, HR, IE, IT, LT, LU,LV, NL, NO, PT, RO, SE, SI, SK, TR I2H G20 20HU I2H G20 25DE, LU, PL, RO I2E G20 20BE I2E(R) G20 20FR I2E(r) G20/G25 20/25FR, NL I2L G25 25RO I2L G25 20FI, HU,NL, RO I3P G31 30BE, CH, CZ, ES, FR, GB, GR, HU, IE, IT, LT, NL, PL, PT, SI, SK,HR I3P G31 37AT, BE, CH, CZ, DE, ES, FR, GB, GR, HU, NL, SK I3P G31 50NOTE: For installations up to 2000ft. units being installed at higher elevation must be configured accordingly at the factoryor modified at the installation site by a factory authorized service technician.