Garmin AT Rev --© 2004 Garmin AT GX Service Manual 7-51Receiver SensitivityStep General Instruction Specific Instructions Expected Results1 Set all testequipment asspecified in TestEquipment Setup onpage 7-17.2 Sig. Gen. Mod Lvl.to 30%.Amplitude to 1000μV.On the HP8920:1. Set AFGen1 to AM 30%.2. Set AMPLITUDE to 1000μV.3. Set Ext. Load R 4 ohms.3 Move test cable. On the test box, connect theHP8920 audio in cable to SPKROUT.4 Adjust volumecontrol on Commradio for 12 W.On the Comm radio, adjust thevolume control until the AC Levelreads 12 watts.≥12 watts output into 4 ohmload (mounted in test fixture) ata volume level from 0 to 12watts.5 Open squelch. On the Comm radio, pull theSquelch knob out (disablesquelch).6 Get SINAD readingand record.On the HP8920:1. Set the value field in theSINAD meter reading toaverage (AVG) at 10 dB.2. Set AMPLITUDE using the ↓down arrow until the SINADmeter reads 6 dB SINAD.3. Record AMPLITUDE.<2 μV (hard) for 6 dB S+N/Nwith 30% modulation at 1000Hz modulation.7 Repeat. Repeat step 6 for 118.00 MHzand 136.975 MHz.