CS 5000User Manual© 2009 GARRETT METAL DETECTORS 42 PN 1530100 REV H7. Reconnect the Power Supply Module and Battery Pack Module as shown;8. Reassemble the system and test.11.7 OPTIONAL STABILIzER BASE INSTALLATION (P/N 1603900)TOOLS REQUIRED PARTS LIST• 1/4” Electric Drill Motor • 2-Mounting Plate• 1/4” (6mm) Nut Driver or Hex Socket • 4-Screw #8x2” Self-Tapping 1/4”• Tape Measure •1-Drill Bit 3/32”• #2 Phillips Screwdriver •1-Instruction SheetProcedure (NOTE: Install mounting plates before assembling the archway)11.7.1 Examine the location and determine the best routing for the power cord.11.7.2 For each panel, remove and discard the two (2) rubber bumpers located on the bottom of thepanels. these holes will be used for attaching mounting plates to panels.11.7.3 Using the supplied 3/32” (2.3mm) drill bit, extend the depth of the mounting holes to 2”(50mm) deep.11.7.4 Attach the plates (with the edges pointing away from the panel using the supplied 2” long screws.CAUTION:The power cord must be installed in the correct Panel location (see Page 8, 3.2.2) before the platecan be secured. DO NOT PINCH the cord between the panel and the plate. Ensure that the head ofthe screw is tight against the plate to prevent the panels from sliding.11.7.5 Assemble the unit.11.7.6 Place unit in upright position at selected operating location.