in.xe TechBook9Electrical wiring for North American model of the in.xeElectrical wiring for North American or CE model of the in.xeMain electrical box GFCI panelWarning!For units for use in other than single-familydwellings, a clearly labeled emergency switch shallbe provided as part of the installation The switchshall be readily accessible to the occupants andshall be installed at least 5' (152 m) away, adjacentto, and within sight of the unit-----This product must always be connected to a circuitprotected by a ground fault interrupterProper wiring of the electrical service box, GFCIand inxe terminal block is essential!Check your electrical code for local regulationsOnly copper wire should be used, neveraluminum-----Disposal of the productThe appliance (or the product) must bedisposed of separately in accordance withthe local waste disposal legislation in forceTo install the wiring for the inxe spa control, you'll needa Phillips screwdriver and a flat screwdriverLoosen the 2 screws of the spa pack door and open itRemove 55" (142 mm) of cable insulationStrip away 1" (25 mm) of each wire insulationPull the cable through the cutout of the boxand secure it with a strain relief (1" NPT strain relief;hole diameter: 1335")(For CE use an IEC certified plastic bushing that willmaintain the IPX5 rating)Make sure that only the uncut sheathing is clampedat this openingPush the color-coded wires into the terminals asindicated on the sticker and use the flat screwdriverto tighten the screws on the terminalsAfter making sure wire connections are secure, pushthem back into the box and close the door Tightenthe 2 screws of the spa pack doorConnect the bonding conductor to the bonding lug onthe front of the inxe spa pack (a grounded electrodeconductor shall be used to connect the equipmentgrounding conductors)in.xe connectionsbonding lug