5 - 24 DPL-25S • DPL-30S • DPL-35S Super Series Part No. 40462September 2016Section 5 - Troubleshooting Flow ChartsChart 11AuxiliaryPlatformLoweringWill NotOperateCheck the low auxillarybattery indicator (redLED) light. If on, it isshowing a low voltagecondition.offonDisconnect the mainpower source. Check forpower at terminal 9 and9A of the 13 pole terminalstrip (J1) located in theground control box.Replace the 8 -1.5V, AAsize batteries.0V DCReplace the P.C. boardOR contact GenieIndustries ServiceDepartment.If power is seen then thesymptom would be thatthe auxillary loweringfrom the platform wouldwork and not from theground control box.wontlowerfrombaseReplace the auxillarydown N.O. contact blocklocated in the groundcontrol box OR repair thered wire from terminal 9aof 13 pole terminal strip(J1).Check for power atterminal 1 of the 3 poleterminal strip (J2) in theground control box.Putthe positive lead ofvoltage meter on terminal1 and the negative leadon terminal 2 thegrounding terminal.0V DC12V DCCheck the auxillarylowering battery holderwires (red wire connectsto terminal 1 and blackwire connects to terminal2) for loose connectionsat the J2 terminal stripOR check for defects inthe battery holder and itswires.Check the auxillarylowering battery holder tomake sure that thebatteries have beeninstalled.yesInstall the 8 - 1.5V, AAsize batteries.nobadCorrect the looseconnections at the J2terminal strip ORReplace the batteryholder.12V DC