Part No. 82315 Genie Z-60/34 13Operator's ManualFourth Edition · First PrintingMaintenanceObserve and Obey:Only routine maintenance items specified in thismanual shall be performed by the operator.Scheduled maintenance inspections shall becompleted by qualified service technicians,according to the manufacturer's specificationsand the requirements specified in theresponsibilities manual.Maintenance Symbols LegendThe following symbols have beenused in this manual to helpcommunicate the intent of theinstructions. When one or more ofthe symbols appear at thebeginning of a maintenanceprocedure, it conveys the meaningbelow.Indicates that tools will be required toperform this procedure.Indicates that new parts will be required toperform this procedure.Indicates that a cold engine is requiredbefore performing this procedure.Check the Engine Oil LevelMaintaining the proper engine oil level is essentialto good engine performance and service life.Operating the machine with an improper oil levelcan damage engine components.Check the oil level with theengine off.1 Check the oil dipstick.Ford models:Result: The oil level should be between the ADDand SAFE marks. Add oil as needed.Deutz models:Result: The oil level should be within the twomarks on the dipstick. Add oil as needed.Ford LRG-425 EFI EngineOil viscosity requirementsbelow 60°F / 15.5°C 5W-30-10° to 90°F / -23° to 32°C 5W-30above -10°F / -23°C 5W-30above 25°F / -4°C 10W-30Use oils meeting API classification SH or SG grade.Units ship with 10-40 CC/SG.