2 Genie Z-60/34 Part No. 82315Operator's Manual Fourth Edition · First PrintingSAFETY RULESElectrocution HazardsThis machine is not electrically insulated and willnot provide protection from contact with orproximity to electrical current.Maintain safe distances from electrical power linesand apparatus in accordance with applicablegovernmental regulations and the following chart.Voltage Minimum SafePhase to Phase Approach DistanceFeet Meters0 to 300V Avoid Contact300V to 50KV 10 3.150KV to 200KV 15 4.6200KV to 350KV 20 6.1350KV to 500KV 25 7.6500KV to 750KV 35 10.7750KV to 1000KV 45 13.7Allow for platform movement, electrical line sway orsag and beware of strong or gusty winds.Keep away from the machine if it contactsenergized power lines. Personnel on the groundor in the platform must not touch or operate themachine until energized power lines are shut off.Do not use the machine as a ground for welding.Tip-over HazardsOccupants and equipment shall not exceed themaximum platform capacity.Maximum platform capacity 500 lbs 227 kgMaximum occupants 2Do not raise or extend the boom unless themachine is on a firm, level surface.Do not depend on the tilt alarm as a level indicator.The tilt alarm sounds in the platform only when themachine is on a severe slope.If the tilt alarm sounds:Do not extend, rotate or raise the boom abovehorizontal. Move the machine to a firm, levelsurface before raising the platform. If the tilt alarmsounds when the platform is raised, use extremecaution to retract the boom and lower the platform.Do not rotate the boom while lowering. Move themachine to a firm, level surface before raising theplatform.