1-9poe temperature-protectionSyntaxpoe temperature-protection enableundo poe temperature-protection enableViewSystem viewParameterNoneDescriptionUse the poe temperature-protection enable command to enable PoE over-temperature protection onthe switch.Use the undo poe temperature-protection enable command to disable PoE over-temperatureprotection on the switch.The PoE over-temperature protection operates as follows:The switch disables the PoE feature on all ports when its internal temperature exceeds 65°C (149°F) forself-protect, and restores the PoE feature settings on all its ports when the temperature drops below60°C (140°F).By default, PoE over-temperature protection is enabled on the switch.You can use the display poe temperature-protection command to display whether PoEover-temperature protection is enabled on the switch.Example# Disable PoE over-temperature protection on the switch. system-viewSystem View: return to User View with Ctrl+Z.[Sysname] undo poe temperature-protection enableThe temperature protection is disabled.poe updateSyntaxpoe update { refresh | full } filenameViewSystem viewParameterrefresh: The refresh update mode is used when the PSE processing software is available. The refreshupdate mode is to upgrade the original processing software in the PSE.