2-12 RMON Configuration CommandsRMON Configuration Commandsdisplay rmon alarmSyntaxdisplay rmon alarm [ entry-number ]ViewAny viewParametersentry-number: Alarm entry index, in the range 1 to 65535.DescriptionUse the display rmon alarm command to display the configuration of a specified alarm entry or all thealarm entries. The configuration information includes: sampling type, sampled node, sampling interval,rising and falling thresholds that trigger alarms, the condition under which an alarm is triggered, and thelast sampled value.Related commands: rmon alarm.Examples# Display the configuration of all the alarm entries. display rmon alarmAlarm table 1 owned by user1 is VALID.Samples type : absoluteVariable formula : 1.3.6.1.2.1.16.1.1.1.4.1Sampling interval : 20(sec)Rising threshold : 100(linked with event 1)Falling threshold : 10(linked with event 2)When startup enables : risingOrFallingAlarmLatest value : 5510006Table 2-1 display rmon alarm command output descriptionField DescriptionAlarm table Index of an entry in the alarm entryuser1 Entry owner: user1Valid The alarm entry identified by the index is valid.Samples type Sampling type, which can be absolute or deltaVariable formula The sampled node