3-2Examples# Set the baud rate of synchronous serial interface Serial 2/0/0 at DCE side to 115200 bps. system-view[Sysname] interface serial 2/0/0[Sysname-Serial2/0/0] baudrate 115200clockSyntaxclock { dteclk1 | dteclk2 | dteclk3 | dteclk4 | dteclkauto }clock { dceclk1 | dceclk2 | dceclk3 }undo clockViewSynchronous serial interface viewDefault Level2: System levelParametersdteclk1: Sets the interface clock selection mode to DTE clock option 1.dteclk2: Sets the interface clock selection mode to DTE clock option 2.dteclk3: Sets the interface clock selection mode to DTE clock option 3.dteclk4: Sets the interface clock selection mode to DTE clock option 4.dteclkauto: Sets the interface clock selection mode to DTE autonegotiation.dceclk1: Sets the interface clock selection mode to DCE clock option 1.dceclk2: Sets the interface clock selection mode to DCE clock option 2.dceclk3: Sets the interface clock selection mode to DCE clock option 3.In DTE mode, the synchronous serial interface supports the clock { dteclk1 | dteclk2 | dteclk3 |dteclk4 | dteclkauto } command. In DCE mode, the synchronous serial interface supports the clock{ dceclk1 | dceclk2 | dceclk3 } command.DescriptionUse the clock command to set clock selection mode for the synchronous serial interface.Use the undo clock command to restore the default.By default, on a synchronous serial interface, the DTE-side clock is dteclk1 and the DCE-side clock isdceclk1.This command does not take effect when X.21 DTE cables are used. The DTE-side clock onsynchronous serial interfaces is DTE clock option 3 (dteclk3).A synchronous serial interface can operate as DCE or DTE.z As DCE, the interface provides DCEclk clock to the DTE.