12 - 4 2020/4820/4820 i User’s GuideExample #4: What are the device’s settings for all Codabar selections?Enter: cbr?.Response: CBRENA1[ACK],SSX0[ACK],CK20[ACK],CCT1[ACK],MIN2[ACK],MAX60[ACK],DFT[ACK].This response indicates that the device’s Codabar Coding Enable (CBRENA) isset to 1, or on;the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;the Check Character (CK2) is set to 0, or Not Required;concatenation (CCT) is set to 1, or Enabled;the Minimum Message Length (MIN) is set to 2 characters;the Maximum Message Length (MAX) is set to 60 characters;and the Default setting (DFT) has no value.Trigger CommandsYou can activate and deactivate the image scanner with serial trigger com-mands. First, the image scanner must be put in Manual/Serial Trigger Modeeither by scanning the Manual/Serial Trigger Mode barcode (page 4-4), or bysending the Manual/Serial Menu Command (page 12-10). Once the imagescanner is in serial trigger mode, the trigger is activated and deactivated bysending the following commands:Activate: SYN T CRDeactivate: SYN U CRThe image scanner scans until a barcode has been read, until the deactivatecommand is sent, or until the serial time-out has been reached (see "ReadTime-Out (Serial Trigger Mode)" on page 4-4 for a description, and the serialcommand on page 12-10).