3800i/3800r User’s Guide 1 - 9Wand Emulation Plug & PlayIn Wand Emulation mode, the imager decodes the bar code then sends data inthe same format as a wand imager. The Code 39 Format converts allsymbologies to Code 39.The Same Code Format transmits UPC, EAN, Code 128 and Interleaved 2 of 5without any changes, but converts all other symbologies to Code 39.TheWand Emulation Plug & Play Code 39 Format bar code below sets theterminal ID to 61. TheWand Emulation Plug & Play Same Code Format barcode sets the terminal ID to 64. These Plug & Play bar codes also set theTransmission Rate to 25 inches per second, Output Polarity to black high, andIdle State to high. (If you want to change the terminal IDonly, without changingany other imager settings, please refer to Wand Emulation Connection on page2-11.)IBM 4683 Ports 5B, 9B, and 17 InterfaceScan one of the following “Plug and Play” codes to program the imager for IBM4683 Port 5B, 9B, or 17.Note: After scanning one of these codes, you must power cycle the cashregister.Wand Emulation Same CodeWand Emulation (Code 39 Format)IBM 4683 Port 5B InterfaceIBM 4683 Port 9B HHBCR-1 InterfaceIBM 4683 Port 17 InterfaceIBM 4683 Port 9B HHBCR-2 Interface