6 - 2 Quick Check® SV Series User’s Guide~BCa##bc{…bbb…}{…mmm…}{…bbb…}… {etc. up to 32 characters max.}Check for specific dataThis command sets (enables) or clears (disables) one of 10 available data matcharrays. All ten arrays may be active simultaneously. A data match error occursif at least one array is active and the data scanned does not match the dataprogrammed in the array. Each array can be up to 32 characters in length.Multiple portions of each array can be masked and the mask character is definedin the command. The data in the array must consist of printable ASCII characterswith ASCII values less than 128.~BC Data Match Commanda 1 digit. A number between 0 and 9. It identifies the datamatch array being programmed or cleared.## Number of data characters in the Data Match array. Thevalue can be 01 through 32.A value of 00 clears (disables)this array.b This character defines the fill character for masking pur-poses. This character cannot be a character to be matchedin the match field mmm.c This character defines the size of the data match field to befixed (“f”) or variable (“v”). If variable, the data in the field isleft justified in a 32 character possible field....bbb... Fill characters prior to the Data Match text. These charac-ters must match the character defined by b in the command....mmm... Data Match Character Field. This can be from 1 to 32 char-acters. These define the exact characters that must bematched....bbb... Fill characters after to the Data Match text (if needed).