Diagnostic Error Code FRU/Action015-015-XXXUSB port External Loopbackfailure 1. Remove USB device(s) and re-test2. System board015-027-XXXUSB port Configuration/Setuperror 1. Flash the system2. System board015-032-XXXUSB port Device Controller failure 1. System board015-034-XXXUSB port bufferallocation failure 1. Reboot the system2. Flash the system3. Run memory test4. System board015-035-XXXUSB port Reset condition detected 1. Remove USB device(s) and re-test2. System board015-036-XXXUSB port Register error 1. System board015-040-XXXUSB port IRQ failure 1. Run setup and check for conflicts2. Flash the system3. System board015-195-XXXUSB port Test aborted by user 1. Information2. Re-start the test, if necessary015-196-XXXUSB port test halt, error thresholdexceeded 1. Press F3 to review the log file2. Re-start the test to reset the log file015-197-XXXUSB port test warning 1. Make sure the component that is called out isconnected and/or enabled2. Re-run test3. Component that is called out in warning statement4. Component under test015-198-XXXUSB port test aborted 1. If a component is called out, make sure it isconnected and/or enabled2. Flash the system and re-test3. Go to the ″Undetermined problems″ section015-199-XXXUSB port test failed, causeunknown 1. Go to the ″Undetermined problems″ section2. Flash the system and re-test3. Replace component under function test018-000-XXXPCI Card Test Passed 1. No action10 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,6649