Diagnostic Error Code FRU/Action020-197-XXX PCI test warning 1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test020-198-XXX PCI test aborted 1. If a component is called out, make sureit is connected and/or enabled2. Flash the system and re-test3. Go to the ″Undetermined problems″section020-199-XXX PCI test failed, cause unknown 1. Go to the ″Undetermined problems″section2. Flash the system and re-test3. Replace component under function test020-262-XXX PCI system error 1. PCI card2. Riser card, if installed3. System board025-000-XXX IDE interface Test Passed 1. No action025-00X-XXX 025-01X-XXX IDE interfacefailure 1. IDE signal cable2. Check power supply3. IDE device4. System board025-027-XXX IDE interfaceConfiguration/Setup error 1. IDE signal cable2. Flash the system3. IDE device4. System board025-02X-XXX 025-03X-XXX 025-04X-XXX IDEInterface failure 1. IDE signal cable2. Check power supply3. IDE device4. System board025-195-XXX IDE interface Test aborted byuser 1. Information2. Re-start the test, if necessary025-196-XXX IDE interface test halt, errorthreshold exceeded 1. Press F3 to review the log file2. Re-start the test to reset the log file025-197-XXX IDE interface test warning 1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under testChapter 7. Symptom-to-FRU index 59