Diagnostic Error Code FRU/Action175-197-XXX Thermal Sensor(s) test warning 1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test175-198-XXX Thermal Sensor(s) test aborted 1. If a component is called out, make sureit is connected and/or enabled2. Flash the system and re-test3. Go to ″Undetermined problems″ section175-199-XXX Thermal Sensor(s) test failed,cause unknown 1. Go to the ″Undetermined problems″section2. Flash the system and re-test3. Replace component under function test175-250-XXX 175-251-XXX Thermal Sensor(s)limit error 1. Check fans2. Check Power supply3. Microprocessor4. System board185-000-XXX Asset Security Test Passed 1. No action185-XXX-XXX Asset Security failure 1. Flash system2. System board185-278-XXX Asset Security ChassisIntrusion 1. Assure Asset Security Enabled2. C2 Cover Switch3. System board201-000-XXX System Memory Test Passed 1. No action201-XXX-XXX System Memory error 1. Replace the memory module called outby the test2. System board202-000-XXX System Cache Test Passed 1. No action202-XXX-XXX System Cache error 1. Cache, if removable2. System board3. Microprocessor206-000-XXX Diskette Drive Test Passed 1. No action206-XXX-XXX Diskette Drive error 1. Diskette Drive Cable2. Check power supply voltages3. Diskette drive4. System board215-000-XXX CD-ROM Drive Test Passed 1. No action215-XXX-XXX CD-ROM Drive error 1. CD-ROM Drive Cable2. Check power supply voltages3. CD-ROM drive4. System boardChapter 7. Symptom-to-FRU index 65