v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing, System x3800 Type 8866,” on page 107 to determine which components arecustomer replaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.Error code Description Action180-xxx-008 Failed I/O board LED test. 1. Reseat the I/O board.2. Replace the I/O board.180-xxx-009 Failed Active ™ PCI LED test. 1. Reseat the following components:a. (Trained service technician only) PCI switchcard assemblyb. I/O board2. Replace the components listed in step 1 one at atime, in the order shown, restarting the servereach time.201-198-000 Memory Test Aborted: Could not run thetest; suspect microprocessor tray error. 1. Restart the server.2. Run the diagnostic test again.3. Reinstall the diagnostic programs (see “Updatingthe firmware” on page 157).4. (Trained service technician only) Replace themicroprocessor tray.201-198-00n Memory Test Aborted: Could not run thetest.Note: n = 1-9 (programming error).1. Restart the server.2. Run the diagnostic test again.3. Reinstall the diagnostic programs (see “Updatingthe firmware” on page 157).201-xxx-CBN Failed Memory Test: See “Memory card andmemory module (DIMM)” on page 124.v C = memory card [1-4]v B = physical bank [1-2]Note: Bank 1 = DIMMs 1 and 3; Bank 2= DIMMs 2 and 4v N = failing DIMM [1-4]1. Reseat the following components:a. DIMM Nb. Memory card C2. Replace the components listed in step 1 one at atime, in the order shown, restarting the servereach time.Note: N = 9 indicates both DIMMs in physical bankB and memory card C.202-xxx-0nn Failed system cache test, where nn=APICID.APIC ID Microprocessor00, 01 106, 07 210, 11 316, 17 41. Reseat the following components:a. (Trained service technician only)Microprocessor nnb. Microprocessor tray2. Replace the following components one at a time,in the order shown, restarting the server eachtime:a. (Trained service technician only)Microprocessor nnb. (Trained service technician only)Microprocessor trayChapter 2. Diagnostics 75