1 Left and Right Inner Rails 5 Top-Rail Flange Screw (Rear)2 Left Rail Label 6 Rear-Rail Alignment Pins3 Left Rail Assembly 7 Rail-Length Adjusting Plate4 Right Rail Assembly 8 Inner-Rail Safety Release Latch2. Remove the front rack door, and if necessary, remove the rear rack door. For 7014 Model T00 and T42racks, refer to 7014 Model T00 and T42 Rack Installation and Service Guide, order numberSA38-0577, for information about removing the rack doors.3. If you do not have a rack-mounting template, go to step 4. Using the rack-mounting template,determine where in the rack to place the system. Make note of the Electronics Industries Association(EIA) location number.Note: The rack-mounting template has printed illustrations located on the front of the template. Eachillustration is designed to aid in identifying the EIA location holes used when planning topopulate your rack. Do not use the rack-mounting template without reading and understandingthe following substeps. Each step must be completed in its entirety.Attention: Mounting the rails is a complex procedure. To install the rack rails correctly, you mustread, and then perform each procedure step in the order given. Failure to perform each step in theorder given may cause rail failure.4. Note the following when using the rack-mounting template:v Each black or white unit on the template is equal to 1 EIA unit.v Each EIA unit consists of three holes.v The EIA units illustrated on the template must be aligned with an EIA unit located on the rack.v It is not necessary to align like-colored EIA units. For example, a black EIA unit illustrated on therack-mounting template does not have to be aligned with a black EIA unit located on the rack. Ablack EIA unit on the rack-mounting template can be aligned with a white EIA unit located on therack. See the following illustration.Appendix D. Setting Up the System 569