22IDS 805 Installer Manual 700-266-02H Issued September 2009For the correct operation of this switch, refer to Section 8: Hardware Reset Switch.LOCATIONS 22-41 Programmable Output ControlsSEE: LOCATIONS 158 - 170 for Additional Programmable OutputsThese locations control the functioning of the 5 onboard programmable outputs. If a smoke detector,strobe light (or any other device requiring power) is connected to a programmable output, a relay boardmust be used to provide the high current. Please refer to the Section 5. Programmable Outputs.Multiple events may be programmed to a single output. The output may be programmed to function asfollows: Output pulsed for two seconds. Output may be latched high. Output may be latched low.Table 6: Output OptionsProgrammable Output Program ValuePulsed Set Port High Set Port LowOutput 1 1 6 11Output 2 2 7 12Output 3 3 8 13Output 4 4 9 14Output 5 5 10 15 The strobe and fire-detect outputs may only be programmed with [0] to [5] i.e. a pulsed output. The second phone number dialled output can only be programmed with values [1] - [5] ([0] willdisable the output).