9IDS 805 Installer Manual 700-266-02H Issued September 20093. End-of-Line Resistors/Tamper per Zone All zones are end-of-line supervised. Any unused zones must also be terminated with theappropriate resistor. The end of line resistor should be placed inside or as close to the sensor as possible. If the zones are not programmed to report tamper by zone i.e. a [0] is programmed into location11 then use the 3K3 end-of-line resistor. If the zones are programmed to report tamper by zone, the 4K7 and 12K end-of-line resistorsshould be connected as per Figure 2 below. The 4K7 and 12K resistors are not included with thepanel but may be obtained from your local distributor of IDS products.Figure 2: Tamper per Zone ConnectionThe operation of the tamper is as follows: If the panel is not armed and a tamper condition occurs, the siren will not sound but a tampercondition will be reported. If the panel is armed and tamper condition occurs the alarm will register a zone violation and atamper condition will be reported. Regardless of whether the panel is armed or not, if a zone is programmed as a priority/paniczone, a tamper will register a panic condition as well a tamper condition. If the tamper per zone is enabled, it affects all zones and therefore both end-of-line resistorsmust be connected in all zones. If the tamper facility is not used on a zone then the 12K resistormust be connected directly across the zone (i.e. between the zone input and ground) and the4K7 resistor is used as the normal end-of-line resistor. The colour codes for the 12K and 4K7 resistors are as seen in Figure 3 below.Figure 3: Resistors Used for Tamper per Zone