IDS805 USER MANUAL NO. 700-266-01A ISSUED NOV 2003 VER 1.00 21IDS805 USER MANUAL11.3 Maids CodeThe maids code (user 14) may be used to limit access to thepremises. The maids code will only disarm the system if the samecode was used for arming. If armed with a code other than a maidscode, the system will view an attempt to disarm with the maids codeas an invalid entry. Any valid user code will disarm the system if it hasbeen armed with the maids code.EXAMPLE:If a maid is expected on a Monday, arming the system on a Mondaymorning using the maids code will allow the maid to disarm thesystem. On days that any other user code (i.e. not a maids code) hasbeen used to arm the system entering the maids code will not disarmthe system.12. Stay ZonesStay zones are those zones which are bypassed automatically whenthe system is STAY ARMED . To avoid triggering the alarm, zonessuch as bedrooms, or other areas which require access, must bebypassed. Stay zones need only be programmed once. Each time thesystem is armed in the stay mode the preselected stay zones will bebypassed automatically.12.1 To Program Stay Zones[3] + [ZONE NUMBER] + [!!!!!] + [#]1. Hold down the [3] key until the keypad buzzer sounds. TheAWAY indicator will flash to show that the panel is in the StayZone programming mode.2. Press the [ NUMBER ] corresponding to the zone you wish to be aSTAY zone followed by the [!!!!!] key.3. The relevant zone indicator will illuminate. (Buzz zones will beshown by flashing indicators. See Section 13. A Buzz zonecannot be selected as a Stay zone; the Buzz status must becleared first.)4. Repeat step 2 until all stay zones are selected.